Comparative Study of Tissue Equalization Techniques in Digital Radiography

WANG Jun,GAN Quan,CHEN Xin-pei. Department of Radiology,General Hospital of Nanjing Military Region,210002,P.R.China  
Objective:To study the tissue equalization with a large area amorphous silicon flat panel detector in soft copy and compared with?Methods:100 posteroanterior and 50 lateral chest radiographs were obtained using a digital flat-panel detector radiography system. The structures studied in the images of posteroanterior view of chest radiographs were the pulmonary apex, pulmonary vessels in the retrocardiac and retrodiaphragmatic regions,descending aorta and the upper margin of the sixth thoracic vertebrae etc..In the lateral view,the anatomic structures consisted of retrocardiac pulmonary vessels,the hili,pulmonary vessels overlapping with heart shadow and the diaphragm,and the upper margin of the third thoracic spine.Differences between the images obtained with tissue equalization were evaluated statistically.Results:Images of tissue equalization are superior in demonstrating the anatomic structures such as the upper margin of the sixth thoracic vertebrae and retrocardiac pulmonary vessels (P0.05) .Conclusion:The wide dynamic range of tissue equalization improves the contrast in poorly penetrated regions (e.g., mediastinum),tissues with different absorption such as bone,pulmonary parenchyma could be simultaneously displayed.
【Fund】: 江苏省教育厅指导性课题(04kjb320046)
【CateGory Index】: R816.4
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 3 Hits
1 WANG Jun,ZHAO Guo-liang,LI Su-jian,et al.Department of Radiology,General Hospital of Nanjing Military Region,Nanjing 210002,P.R.China;A comparison study of absorb dosage of DR dual energy subtraction with DR chest radiography and thoracic CT[J];Radiologic Practice;2011-01
2 Pang Xiao-ping,Wu Nan-zhou,Yang Cheng-huan,Yang Tie,Xiao Yue-yongDepartment of Radiology,General Hospital of Chinese PLA,Beijing 100853,China;Application of tissue equalization technique of direct digital radiography in cervical spine-thoracic spine[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2010-17
3 WANG Jun1,2,WU Yuan-chu1,2,ZHAO Guo-liang3,DING Jin-hua41.Southern Medical University Guangzhou 510515,P.R.China2.Department of Radiology,General Hospital of Nanjing Military,Nanjing 210002, P.R.China3.Disease Control Centre of Nanjing Military Region,Nanjing 210002,P.R.China4.No 65535 Haspital of PLA,Liaoning 115200,P.R.China;To study the absorb dose of CR in bedside with patients[J];Journal of Medical Imaging;2009-11
China Proceedings of conference Full-text Database 1 Hits
1 WANG Jun,ZHAO Guo-liang, LI Su-jian,ZHOU Zheng-liang, ZHANG Yue-yue,CHEN Xin Department of Radiology,General Hospital of Nanjing Military Region,210002,China;A study of absorb doses of DR dual engere subtraction with patients[A];[C];2011
【Citations】
Chinese Journal Full-text Database 1 Hits
1 SU Yan-cheng,GUO Dai-zhu,ZHOU Xiang-tao,HUANG Li-qi(Department of Diagnostic Imaging and Interventional Center,Tumor Hospital,Zhongshan University,Guangzhou 510060,China);The Advantages of Tissue Equalization Technique Applied in DR Chest Photography[J];Journal of Practical Radiology;2004-08
【Co-citations】
Chinese Journal Full-text Database 8 Hits
1 LIU Guang-hu,GUI Xiao-hong,LIU Hong,et al.Department of Radiological,Xuzhou No.1 People Hospital,Jiangsu 221002,P.R.China;Application of DR Tissue Equalization in Fracture of Rib[J];Radiologic Practice;2010-02
2 TANG Hui,WANG Ji,YIN Yan,et al.Department of Radiology,Renji Hospital,the Medical College of Shanghai Jiaotong University,Shanghai 200001,P.R.China;Comparison between direct digital radiography and tissue equalization in diagnosis of nasal bone trauma[J];Radiologic Practice;2010-08
3 YU Jian-ming,YANG Ming,LEI Zi-qiao,HU Li (Department of Radiology of Union Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430022,Hubei,China);The clinical application value of DR tissue equalization technique on lesion of thoracic and lumbar vertebras[J];Biomedical Engineering and Clinical Medicine;2008-01
4 HUA Jian-ming,WANG Zhi-kang,ZHANG Wei-min(Department of Radiology,the Second Affiliated Hospital,Medical College of Zhejiang University,Hangzhou 310009,China);Application of Latitude Reduction Technique in CR Foot Radiography[J];Journal of Practical Radiology;2006-01
5 SONG Li-jun,WANG Wei,CUI Guang-bin,WEI Long-xiao,WANG Ya-rong,BAI Jian-jun(Department of Radiology, Tongdu Hospital,the Fourth Military Medical University,Xi’an 710038,China);Evaluation of Equalization Technic on Cervical DR Images[J];Journal of Practical Radiology;2007-06
6 Pang Xiao-ping,Wu Nan-zhou,Yang Cheng-huan,Yang Tie,Xiao Yue-yongDepartment of Radiology,General Hospital of Chinese PLA,Beijing 100853,China;Application of tissue equalization technique of direct digital radiography in cervical spine-thoracic spine[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2010-17
7 ZHOU Yu, QI Yue-yong,JING Kai-yu, XI Dao-you (Xinqiao Hospital, the Third Military Medical University, Chongqing 400038, China);Tissue Equalization Technique Applied in DR Thoracolumbar Vertebral Body Photography[J];Chinese Medical Equipment Journal;2008-10
8 YU Jian-ming LEI Zi-qiao YANG Ming Department of Radiology,Union Hospital Affiliated,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430022,China;Application study of digital X-ray tissue equalization technique in the femoral neck injury[J];Chinese Journal of Radiology;2007-08
【Co-references】
Chinese Journal Full-text Database 9 Hits
1 WANG Yi-zhan,FU Qiang,GAO Zhen-long,ZHANG Zheng (Department of Radiography,The First Affiliated Hospital,Chinese Medical University ,Shenyang 110001,Liaoning,China);Study on DR with tissue equalization technical in cervical vertebra oblique projection[J];Biomedical Engineering and Clinical Medicine;2006-06
2 YU Jian-ming,YANG Ming,LEI Zi-qiao,HU Li (Department of Radiology of Union Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430022,Hubei,China);The clinical application value of DR tissue equalization technique on lesion of thoracic and lumbar vertebras[J];Biomedical Engineering and Clinical Medicine;2008-01
3 SU Yan-cheng,GUO Dai-zhu,ZHOU Xiang-tao,HUANG Li-qi(Department of Diagnostic Imaging and Interventional Center,Tumor Hospital,Zhongshan University,Guangzhou 510060,China);The Advantages of Tissue Equalization Technique Applied in DR Chest Photography[J];Journal of Practical Radiology;2004-08
4 LUO Qing,ZHANG Guo-hua(Department of Radiology,No.2 People's Hospital of Wuxi,Jiangsu Province 214002,China);Clinical Evaluation of Pulmonary Nodules and Calification in Nodules with Dual-energy Subtraction Digital Radiography[J];Journal of Practical Radiology;2006-01
5 DENG Xing-jie (Huizhou Central People's Hospital, Huizhou, Guangdong 516001, China);Organize the Balanced Technique in DR Neek Thoracic Vertebrae[J];Journal of Practical Medical Techniques;2006-13
6 CHEN Jian-xin, CHEN Zi-qian, ZHAO Chun-lei(Fuzhou General Hospital, Nanjing Military Area Command, Fuzhou 350025, China);Application of Digital Radiography with Dual-energy Subtraction in Coronary Artery Calcification[J];Chinese Medical Equipment Journal;2008-04
7 WANG Yanhua, HUANG Hongyuan. Department of Radiology, Shanghai Gongli Hospital, Shanghai 200135,China;Diagnostic value of direct digital radiography(DR) tissue equalization in chidren snoring disease caused by tonsil and adenoid vegetation[J];Shanghai Medical Imaging;2005-02
8 YU Jian-ming LEI Zi-qiao YANG Ming Department of Radiology,Union Hospital Affiliated,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430022,China;Application study of digital X-ray tissue equalization technique in the femoral neck injury[J];Chinese Journal of Radiology;2007-08
9 WANG Gang1, CHEN Wei-guo2, ZHENG Xiao-lin1, CAI Yu-xing2(1.Department of Radiology, Dongguan People’s Hospital, Dongguan 523018, China;2.Department of Radiology, Nanfang Hospital, Southern Medical University, Guangzhou 510515, China);Evaluation of normal lung markings with digital dual energy subtraction radiography[J];Chinese Journal of Medical Imaging Technology;2008-09
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 ;Investigation of Developmental Strategy About Digital Radiologic Equipment′s Update[J];Journal of Practical Radiology;2002-11
2 ZENG Qing si, CEN Ren li, CHEN Ling, HE Jian xun, LIN Han fei Department of Radiology, First Affiliated Hospital, Guangzhou Medical College, Guangzhou 510120,China;Comparison of the quality of the chest film between digital radiography and conventional high kV radiography[J];Chinese Journal of Radiology;2003-02