Molecularly Imprinted Photonic Crystal for Detection of Glucose
XUE Fei,DUAN Ting-Rui,XUE Min,LIU Feng,WANG Yi-Fei,WEI Ze-Quan, WANG Miao,ZHANG Pan,YUAN Zi-Gao,MENG Zi-Hui(School of Chemical Engineering and the Environment,Beijing Institute of Technology,Beijing 100081)
A three-dimensionally ordered,macroporous,inverse-opal glucose molecularly imprinted polymer crystal(MIPC) film was synthesized by the inverted colloidal-crystal template technique.Preparation of our MIPC was carried out by thermo-poymerization of monomers(2-hydroxyethyl methacrylate and N-isopropylacrylamide),covalent recognizer(4-ethylenyl phenylboronic acid),and cross-linker(N,N′-Methylenebisacrylamide) with poly(methyl-methacrylate)(PMMA) particle array as template,followed by chemical removal of the template using acetone.Due to its 3D-ordered macroporous arrays with molecular imprinting,nanocavities,the formed photonic hydrogel allows rapid and selective detection of the target glucose.The glucose adsorption amount of our MIP was 3.2 mg/g in 3 min which is two times more than that of other analogues.The diffraction wavelength of the MIPC redshifts was more than 150 nm in response to 0.02 mol/L of glucose.Our results revealed that MIPC could provide a novel non-invasive approach for glucose detection in tears or urine and exhibit a promising potential for development of new glucose monitoring technology.
|
|
| Chinese Journal Full-text Database |
2 Hits
|
|
|
| 1 |
YANG Qing-De1,2,LIU Hong-Min1,2,LIU Chun-Xiu 1,2,HE Yin-Zeng1,2,TIAN Qing1,2,Cai Xin-Xia1,2 1 ( State Key Laboratory of Transducer Technology,Institute of Electronics,Chinese Academy of Sciences,Beijing 100190) 2 ( Graduate School of Chinese Academy of Sciences,Beijing 100190);Study of Key Electrochemical Problems in Transdermal Noninvasive Glucose Monitoring[J];Chinese Journal of Analytical Chemistry;2009-11 |
| 2 |
CHEN Yi1,2*,LI Jincheng1(1.Laboratory of Analytical Chemistry for Life Science,Institute of Chemistry,the Chinese Academy of Sciences,Beijing 100190,China;2.Beijing National Laboratory of Molecular Science,Beijing 100190,China);Photonic crystals for analytical chemistry[J];Chinese Journal of Chromatography;2009-05 |
|
|
|
| Chinese Journal Full-text Database |
1 Hits
|
|
|
| 1 |
Xiao Honghui1,2,Chang Lingqian1,2,Yang Qingde1,2,He Yinzeng1,2,Cai Xinxia1,2(1 State Key Laboratory of Transducer Technology,Institute of Electronics,Chinese Academy of Science,Beijing 100190,China;2 Graduate University of Chinese Academy of Sciences,Beijing 100049,China);Development and experiment of a glucose monitor using noninvasive transdermal extraction[J];Chinese Journal of Scientific Instrument;2010-12 |
|