Full-Text Search:
Home|About CNKI|User Service|中文
Add to Favorite Get Latest Update

Reverse Flow Injection Chemiluminescence Method for the Determination of Tannic Acid

WANG Shu-hao *,WANG Liang-yu,MA Chun-lin (Department of Chemistry,Liaocheng University,Liaocheng,Shandong,252059)  
A simple, rapid and accurate reverse flow injection chemiluminescence method for the determination of tannic acid based on luminol-KIO 4-tannic acid system is developed. The linear range of the determination is 2.0×10 -8 ~ 6.0×10 -6 g/mL for tannic acid. The detection limit is 1.12×10 -9 g/mL. The method has been applied to the determination of the content of tannic acid in Chinese gall and fructus chebulae with satisfactory results.
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.