Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《High Voltage Engineering》 1995-01
Add to Favorite Get Latest Update

The Dispersive Monitoring of Insulation on Line

Zheng Benwang  
In this paper, a kind of dispersive monitoring of the insulation parameters of scveral substaion's high voltage apparatus and the monitoring on line to the transformer's partial discatge(PD) is introduccd. The rcsults showcd that the disperaive monitoring of iusulation is feasible and the measuring accuracy can satisfy the requirements of the field testing.
【CateGory Index】: TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 ;A Measuring Approach of tanδ Based on Artificial Neuron Adaptation[J];High Voltage Engineering;2001-03
2 ;The Design of Distributed On-line Monitoring System of High Voltage Electric Equipments in Substation[J];High Voltage Engineering;2003-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 PENG Li,XU Yan,ZHU Ming?jun (Huazhong University of Science and Technology,Wuhan430074,China);Resistor Divider Voltage Transformer for 10kV System[J];Transformer;2003-11
2 ;Design of HV Divider for Measuring HV Nanosecond Pulse[J];High Voltage Engineering;2002-04
3 ;Discussion on Industrial Production of Rogowski Coil[J];High Voltage Engineering;2003-03
4 OUYANG Jia, LIU Jinliang, TIAN Liang, FENG Jiahuai, LIU Yonggui (College of Science, National University of Defense Techology, Changsha 410073, China);Influence of Different Input Signals with Nanosecond Pulsewidth on Capacitive Voltage Divider[J];High Voltage Engineering;2004-12
5 XU Yan,HAN Shizhong,PENG Li,ZHU Mingjun(School of Electrical & Electronic Engineering,Huazhong University of Science and Technology,Wuhan 430074,China);Study on the Resistive Voltage Transformer[J];High Voltage Engineering;2005-12
6 LV Liang1, WANG Song1, ZHOU Hui-gao2, WANG An2, LI Yan-ming1(1. School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China;2. Xi’an High Voltage Apparatus Research Institute, Xi’an 710077, China);Property of a Broad Bandwidth High Voltage Divider[J];High Voltage Engineering;2007-04
7 Wang Chengyu, Wang Jimei;Measurement of Potential at the Shield of Vacuum Interrupter[J];High Voltage Apparatus;1994-01
8 NIU Hai-qing,LIN Xin(School of Electrical Engineering,S henyang University of Technology,S henyang 110023,China);Studies of error characteristic and structure of new voltage sensor[J];Journal of Shenyang University of Technology;2001-06
9 Yu Cunyi (Department of Electrical Engineering);INFLUENCE OF RISE TIME OF A PRACTICAL STEP ON THE STEP RESPONSE TIME[J];Journal of Xi'an Jiaotong University;1988-06
10 Wang Renhuang, Zhu Liang Hunan University;Measuring Dielectric Loss of High Voltage Equipments on Line at Power Frequency[J];Proceedings of the Csee;1988-05
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Feng ying, WANG Yu guang (Taiyuan Transformer Works., Taiyuan 030021, China);Ultrasonic Position Setting Measurement on Partial Discharge of Power Transformer[J];TRANSFORMER;2000-02
2 NIE Peng 1,ZHAO Xue zeng 1,ZHANG Yan 2, BAI Jing feng 1,ZHAO Xue tao 1 (1.Harbin Institute of Technology,Harbin 150001;2.Bei'An Electric Power Bureau.Bei'an Heilongjiang 157011);Study On The On-Line Monitoring System of the Insulation Quality of High Voltage Electric Power Equipment[J];JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING;2000-01
3 ZHANG Wen yu,Luo Ji shou,Liu Ya wei (Departmentof Electric Power Engineering,Northeast China Institute of Electric Power Engineering,Jilin City 132102);The Design on Distributed On-line Supervisory System of High-Voltage Circuit Breaker Based on CAN Bus[J];Journal of Northeast China Institute of Electric Power Engineering;2001-04
4 Xu Xiaoyu,Jiang Yuhong (Wuhan University, Wuhan, 430072);Analysis on the Error Sections of On-line Monitor of HV Apparatus Insulation[J];Electric Power Construction;2003-01
5 Wei Renyong Li Zhiyong Changsha Railway University Changsha, 410075 China;MEASUREMENT OF HARMONICS IN POWER SYSTEM BASED ON ARTIFICIAL NEURAL NETWORK[J];POWER SYSTEM TECHNOLOGY;1999-12
6 Fu Biman Electric Power Research Institute,Ministry of Electric Power Beijing,100085 China;LIVE-LINE MONITORING OF CAPACITIVE APPARATUS IN POWER SYSTEM[J];POWER SYSTEM TECHNOLOGY;1995-05
7 Cai Guoxong;Hu Zhaoming(Electric Power Research Institute,Ministry of Electric Power Beijing 100085,China)wang Jianmin(Langfang Power Bureau,North China Power Administration Langfang 102800,China);MEASURING DIELECTRIC LOSS BY ZERO CROSS POINT VOLTAGE COMPARING METHOD[J];POWER SYSTEM TECHNOLOGY;1995-10
8 Guo Bihong Yang Xiaohong Electric Power Research Institute, State Power Corporation,China Beijing, 100085 China;ANALYSIS ON DEVELOPMENT AND APPLICATION OF ON LINE MONITORING TECHNIQUE FOR ELECTRIC POWER DEVICES IN CHINA[J];POWER SYSTEM TECHNOLOGY;1999-08
9 ;The Application of Digital Waveform Analyzing System in On-Line Monitoring Measurement of Insulatione[J];High Voltage Engineering;1991-03
10 ;A Study of On-Line Monitoring Measurement of tgδ[J];High Voltage Engineering;1994-04
【Secondary References】
Chinese Journal Full-text Database 7 Hits
1 Wang Nan (North China Electric Power University);Analysis and Discuss How to Improve Accuracy for On-line Monitoring Dielectric Loss[J];Electrotechnical Journal;2003-01
2 CHEN Zhuo, LIU Nian, BO Liya (Sichuan University,Chengdu 610065, China);Condition Monitoring and Fault Diagnosis of the Power Equipment[J];High Voltage Engineering;2005-04
3 ;Technology of Closing and Locking of 10 kV Vacuum Circuit Breaker on the Spring Coil Without Stored Energy[J];High Voltage Engineering;2006-03
4 YANG Daliang,CHEN Junling(School of Electrical Engineering,Guangxi University,Nanning 530004,China);On-line Monitoring System Based on DSP and Optical Fiber Technology for High Voltage Equipment[J];High Voltage Engineering;2006-07
5 WANG Rui-chuang,Xiao Shi-wu(Sifang Institute of North China Electric Power University,Beijing 102206,China);Research of On-Iine Monitoring Methods of Dielectric Loss for Capacitive Equipment and Some Suggestions[J];Power Capacitor & Reactive Power Compensation;2009-04
6 LU Fang-cheng1,CHAO Hong-jun2,XU Zhi-niu1,LI He-ming1(1.School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,China;2.Luoyang Power Supply Company,Luoyang 471009,China);Overview of digital method for dielectric loss measurement[J];Journal of North China Electric Power University(Natural Science Edition);2008-06
7 SHAO De-jun, YIN Xiang-gen, LI Yan-wu, HU Wen-ping, WANG Zhi-hua (Huazhong University of Science and Technology,Wuhan 430074,China);Realization of great capacity data memory in data acquisition system for electrical equipment on-line monitoring[J];Relay;2004-12
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved