Analysis of C2H2 in the Purifying Process of Transformer

Li Haiwei  
The transformer oil should be filtered and treated in vacuum, it improves dielectric strength of oil and decreases the water and impurity content in oil. So the chemical and physical characteristics of transformer oil is improved. This has been verified by the example.
【CateGory Index】: TM855
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 1 Hits
1 ;Application of Gas Chromatographic Analysis Technology in Potential Faults Diagnosis of Transformer[J];High Voltage Engineering;2002-08
【Co-citations】
Chinese Journal Full-text Database 4 Hits
1 MA Hongzhong, LI Zheng (Hohai University, Nanjing 210098, China);Transformer Overheating Fault and Synthesis Diagnosis[J];High Voltage Engineering;2005-04
2 ZHOU Ai-hua1,2,ZHANG Bi-de1,ZHANG Hou-xuan1(1.School of Electrical and Information,Xihua University,Chengdu 610039,China;2.Department of Electronic and Information,Sichuan University of Science & Engineering,Zigong 643000,China);Power Transformer Fault Diagnosis by Using the Artificial Immune Classification Algorithm[J];High Voltage Engineering;2007-08
3 SI Zeng-yan(Xuzhou Electric Power Supply Company,Xuzhou 221005,China);Diagnosis and Treatment of Faults in 110 kV Transformers[J];High Voltage Apparatus;2007-02
4 CAO Yonggang~1,ZHOU Ling~1,DING Xiaoqun~1,FENG Lei~2,MA Wenjing~1,WU Zheng~1(1.School of Electrical Engineering,Hehai University,Nanjing 210098,China;2.Shandong Sishui Power Company,Sishui 273200,China);Power Transformer Fault Diagnosis Based on Fuzzy Integral Fusion[J];High Voltage Engineering;2006-03
【Secondary Citations】
Chinese Journal Full-text Database 3 Hits
1 ZHANG Li gang (The General Management Station for Power & Telecommunication under the Shanxi Yellow River Diversion Project, Taiyuan 030002,China);Relation between the Composition & Contents of Dissolved Gases in Transformer Oil and Insulation Fault Diagnosis of Oil-Filled Power Equipment[J];TRANSFORMER;2000-03
2 He Hongqun Electricity-Supply Division of Xiangfan Railway Bureau,Xiangfan 441003;Diagnosis about the Multiple Earthing Fault of Transformer Core[J];TRANSFORMER;1997-08
3 Liu Qingning (Baozhusi Power Plant 628003);Discrimination for Multiplespot Grounding Fault of Transformer Core[J];SICHUAN ELECTRIC POWER TECHNOLOGY;1998-03