Study on maximum dehumidification calculation model of heat pump drying system

Li Haoquan;Liu Qinghua;Wu Yaosen;Long Chengshu;Guangdong Institute of Modern Agricultural Equipment;  
Calculation model of maximum dehumidification and evaporation temperature for heat pump drying system was derived,and then the error of model was analyzed.Based on the performance parameters of compressor at 0℃~75℃,the relative error of calculated dehumidification and case humidification are -1.931%~1.581% and-0.383%~0.223% respectively,and absolute error of case humidification is-0.017 1~0.015 8 g/s.The calculation model has great significance for the optimal design of heat pump drying system.
【Fund】: “十二五”农村领域国家科技计划课题(2014BAD04B09—2)——水产品高品质干燥技术与装备的研究及应用示范
【CateGory Index】: TU83