Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Acta Optica Sinica》 2016-06
Add to Favorite Get Latest Update

High Power Sub-Picosecond Ultraviolet Calibration Facility and Its Preliminary Application

Deng Keli;Chen Tao;Wang Qiangqiang;Cao Zhurong;Research Center of Laser Fusion,China Academy of Engineering Physics;  
A sub-picosecond ultraviolet calibration facility is established based on the uniform profile of a gas dye laser,and this is specially designed for the inertial confinement fusion diagnosis system calibration.The laser beam operates at 248.5nm with a pulse width of about 0.5ps and a total energy of about 100 mJ,and generates a uniform spot that is about 35 mm×25 mm.Some preliminary calibration results of a high temporal resolution diagnosis system are obtained on the facility,which proves that the parameters of picosecond systems can be calibrated on the facility.Since the energy output is stable,it is possible to develop a quantitative time-resolving calibration technique.
【Fund】: 中国工程物理研究院科学基金(2015B0102016)
【CateGory Index】: TL632
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
Similar Journals
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved