Energy-saving evaluation of seawater source heat pump units based on the dynamic programming

SHU Hai-wen1,LI Xiang-li1,DUAN MU-lin1,ZHU Ying-xin2(1.School of Civil Engineering,Dalian University of Technology,116024 Dalian,Liaoning,China;2.School of Architecture,Tsinghua University,100084 Beijing,China)  
In order to evaluate the energy-saving effect of seawater source heat pump units over conventional water cooled chillers precisely,various factors that affect the energy consumption of chillers are analyzed.Then a mathematical model of optimal chiller loading was set up on the basis of dynamic programming theory.Through a case study of an office building,the steps of optimal selection of heat pumps or chillers with different capacities are brought out based on the principle that the total energy consumption throughout the cooling season is minimized.And the energy-saving of the seawater source heat pump units in the case project is calculated to be 16.3%.The energy-saving evaluation method of seawater source heat pump units provided in the paper can minimize the calculation error as it is based on the optimal selection of different heat pumps or chillers.
【Fund】: 国家“十一五”科技支撑计划项目(2006BAJ03B01);; 大连理工大学青年教师基金项目(893231)
【CateGory Index】: TU831;P74
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 5 Hits
1 SHI Zhi-gang~(1,2),HU Song-tao~2,LI An-gui~1 (1.Xi'an University of Architecture & Technology,Xi'an 710055,Shanxi,China;2.Qingdao Technological University,Qingdao 266033,Shandong,China);Optimal Load Distribution Strategy for Multiple Chiller Water Units[J];Building Science;2007-10
2 By Xia Jianjun ★, Yan Da and Jiang Yi ★Tsinghua University, Beijing, China;Building environment design simulation software DeST(9): simulation and analysis of cooling plants(part 1)[J];Hv & Ac;2005-03
3 By Shi Ling Jimei University, Xiamen, Fujian Province, China;Optimization control strategy in air conditioning system with multi water chillers[J];Hv & Ac;2005-05
4 Yan Xiuying★,Meng Qinglong,Ren Qingchang and Tong Wei★ Xi'an University of Architecture &Technology,Xi'an,China;Optimal load sharing strategy for multiple-chiller systems and its simulation[J];Heating Ventilating & Air Conditioning;2007-11
5 CHEN Dan-dan,JIN Xin-qiao,DU Zhi-min,XIAO Xiao-kun(School of Mechanical Eng.,Shanghai Jiaotong Univ.,Shanghai 200240,China);The Optimal Loading Strategy of Multiple Chillers in HVAC Systems[J];Journal of Shanghai Jiaotong University;2007-06
【Secondary Citations】
Chinese Journal Full-text Database 6 Hits
1 QIU Guang, CAO Jia-cong (College of Environmental Science and Engineering, Donghua University,Shanghai, 200051);Study of Optimization of Load Assignment for Industrial Boiler Plants[J];Journal of Donghua University,Natural Science;2005-02
2 DING Yun-fei;The Evaluation of Influence of Part-load Performance to Chiller Energy Consumption[J];ENERGY CONSERVATION;2000-01
3 By Shi Ling Jimei University, Xiamen, Fujian Province, China;Optimization control strategy in air conditioning system with multi water chillers[J];Hv & Ac;2005-05
4 JIN Xin qiao 1, XIA Jing 1, ZHOU Xing xi 1, WANG Sheng wei 2 (1.School of Power and Energy Eng., Shanghai Jiaotong Univ., Shanghai 200030, China; 2.Dept. of Building Service Eng., The Hong Kong Polytechnic Univ., Hong Kong);On-Line Optimization of Energy Management and Control System for Central Air-Conditioning in Building System[J];Journal of Shanghai Jiaotong University;2001-05
5 JIN Xin qiao, LI Xiao feng, REN Hai gang (School of Mechanical Eng., Shanghai Jiaotong Univ., Shanghai 200030, China);On-line Optimal Control of Variable Water Volume Systems in HVAC Systems[J];Journal of Shanghai Jiaotong University;2003-07
6 CHEN Dan-dan,JIN Xin-qiao,DU Zhi-min,XIAO Xiao-kun(School of Mechanical Eng.,Shanghai Jiaotong Univ.,Shanghai 200030,China);The Optimal Control Strategy for the Operation of Multiple Chillers System Based on Coefficient of Performance(COP) Optimization[J];Journal of Shanghai Jiaotong University;2006-08
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved