Cause Analysis and Improvement of High Ammonia Content in Exhaust Gas Emissions from Melamine Ammonia Scrubber

Li Jinli;Henan Energy Chemical Industry Group,Zhongyuan Dahua Company;  
The paper analyzed the reasons of high ammonia content in exhaust gas emissions from ammonia scrubber, and proceed series technical innovation through system operation optimization. Actual operation results indicated that the ammonia content in exhaust gas emissions from ammonia scrubber was reduced substantially which not only improved the environment, but also reduced the melamine production cost.