Reliability Evaluation of HVDC Transmission System Based on Monte Carlo Method

Jiang Jin-liang Wang Sui Ren Zhen(School of Electric Power,South China University of Technology,Guangzhou 510640,Guangdong,China)  
In order to overcome the drawbacks of the fault tree analysis(FTA) in the reliability evaluation of high-voltage circuit current(HVDC) transmission system,this paper proposes a novel method based on the Monte Carlo method and the FTA.In the proposed method,a fault tree is established according to the causes of system failure and with the component maintenance and backup dependency being considered.The fault tree is then simulated by the improved Monte Carlo simulation technique.Simulated results of a real HVDC transmission system show that the proposed method is feasible and effective.
【Fund】: 国家自然科学基金重点资助项目(50337010)
【CateGory Index】: TM721.1
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 9 Hits
1 Xu Lingling,Ye Tinglu and Zhang Qiping State Grid Corporation of China Zhu Li;Statistics and Analysis on Reliability of HVDC Transmission Systems of SGCC[J];电气(英文版);2010-03
2 YU Xin-qiang(State Grid Corporation of China,Xicheng District,Beijing 100031,China);Statistics and Analysis on Reliability of HVDC Power Transmission Systems of State Grid Corporation of China[J];Power System Technology;2009-12
3 XIE Kaigui,MA Huaidong,HU Bo,CAO Kan,LI Chunyan(State Key Laboratory of Power Transmission Equipment & System Security and New Technology(Chongqing University),Shapingba District,Chongqing 400044,China);Reliability Evaluation of Converter Transformer System in HVDC Transmission System Based on Markov State Space Graph Algorithm[J];Power System Technology;2011-09
4 LIANG Zhifeng;DONG Yu;ZHANG Zhigang;National Electric Power Dispatching and Control Centre;;Statistical Analysis on Forced Outages of HVDC Transmission Systems in State Grid Corporation of China from 2006 to 2012[J];Automation of Electric Power Systems;2014-06
5 Zeng Ai-dong;Xu Qing-shan;Ding Mao-sheng;Lin Zhang-sui;Xu Xiao-hui;School of Electrical Engineering,Southeast University;Ningxia Electric Power Company of State Grid;Power Economic Research Institute,State Grid Fujian Electric Power Co. ,Ltd.;China Electric Power Research Institute ( Nanjing);;Effect of Wind-Storage Complementary Microgrid on Reliability of Power Distribution Network[J];Journal of South China University of Technology(Natural Science Edition);2014-04
6 Xu Baochang1,Chen Yongkun2,Liu Gonghui3(1.China University of Petroleum,Beijing 102249,China,2.Beijing Institute of Strength and Environment Engineering,Beijing 100076,China;3.Beijing Union University,Beijing 100020,China);Reliability analysis of a circular natural gas drilling system[J];Natural Gas Industry;2011-02
7 YANG Yilei,YAO Peng,GUO Xiaobo (QiNan Power Supply Burau,Chongqing Electric Power Company,Chongqing 401420,China);Adequacy Evaluation of Power Generation System with Wind Farm Based on Sequential and Stochastic Wind Speed Models[J];Modern Electric Power;2012-01
8 LI Jing-kui;Reliability analysis of NC machine tool hydraulic system based on monte carlo method[J];Chinese Hydraulics & Pneumatics;2011-11
9 LI Xiao;LIU Chun-bao;GUAN Ting;School of Electromechanical Engineering,Guangdong University of Technology;Guangzhou General Hospital of Guangzhou Military Command;;Modeling and Simulation for the Reliability of Urethra Valve of Bladder Power Pump[J];Journal of System Simulation;2013-12
【Citations】
Chinese Journal Full-text Database 5 Hits
1 ZHANG Jing-wei,REN Zhen,HUANG Wen-ying(South China University of Technology,Guangzhou 510640,China);FTA models and its application in HVDC system evaluation[J];Electric Power Automation Equipment;2005-06
2 LIU Hai-tao, CHENG Lin , SUN Yuan-zhang, ZHENG Wang-qi( Electrical Engineering Department, Tsinghua University, Haidian District, Beijing 100084, China; EHV Power Transmission Company of China Southern Grid, Guangzhou 510620, Guangdong Province, China);RELIABILITY EVALUATION OF HYBRID AC/DC POWER SYSTEMS[J];Power System Technology;2004-23
3 WANG Shi-xiang, GAO Shi-bin (School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan Province, China);Application of Mente Carlo Method in Reliability Evaluation of Integrated Substation Automation[J];Power System Technology;2006-05
4 Wu Guo-yue~1 Jiang Jin-liang~1 Wu Guo-pei~2 Hua Dong~1(1.College of Electric Power, South China Univ. of Tech., Guangzhou 510640, Guangdong, China;2. Guangzhou Power Supply Branch, Guangzhou Power Group, Guangzhou 510245, Guangdong, China);A New Transaction Model and Transmission Congestion Management Method for the Power Market[J];Journal of South China University of Technology(Natural Science);2004-10
5 XIONG Huai\|xin (Institute of Reliability Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China);A New Algorithm for Reliability Simulation Based on Failure Time Function[J];Systems Engineering-theory & Practice;2001-08
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Chen Weijun (Chongqing University);Ultra HVDC Converter System Reliability Evaluation[J];Electrotechnical Application;2007-12
2 WAN Guo-cheng1, REN Zhen1, ZHANG Cong-wen2, ZHUANG Hong2 (1.South China University of Technology, Guangzhou 510640, China; 2.Automation Institute of Industry and Commercial Bank of China, Xiangfan 443002, China);Power Supply Mode of Two UPS Hot Backup System and Its Reliability Index Estimate[J];Power Electronics;2002-06
3 LI Feng1,ZHANG You-fu2,HOU Jian-guo3,AN Xu-wen3,WANG Hong1,LI Biao2(1.China Electric Power Research Institute,Beijing 100055,China;2.SGCC DC Engineering Construction Company, Beijing 100052,China;3.Wuhan University,Wuhan 430072,China);Comparison of Safety Degrees in Design of Transmission Towers Both in China and Abroad[J];Electric Power Construction;2010-06
4 Ren Zhen, Wu Juan (South China University of Technology. 510641, Guangzhou, China)Chen Lifang (Electricity Overhaul Company of the Pearl River, 511458, Guangzhou. China);EQUIVALENT MODEL FOR HVDC RELIABILITY EVALUATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-09
5 Ren Zhen, Liang Zhensheng, Huang Wenying (South China University of Technology, Guangzhou 510640, China);SENSITIVITY ANALYSIS OF AC/DC HYBRID TRANSMISSION SYSTEM RELIABILITY INDICES[J];Automation of Electric Power Systems;2004-14
6 WANG Gang, DING Mao-sheng, LI Xiao-hua, LIAO Zhi-wei (South China University of Technology, Guangzhou 510640, China);Reliability Analysis of UPS for Power System[J];Automation of Electric Power Systems;2005-03
7 REN Zhen, CHEN Bi-yun (South China University of Technology, Guangzhou 510640, China);Improved Reliability Evaluation Model for Complex Transmission Networks[J];Automation of Electric Power Systems;2005-05
8 LI Xiaolin1,CAO Kan2,XIE Kaigui2,WANG Libin2,HUANG Ying1,XU Shukai1(1. China Southern Power Grid Technology Research Center,Guangzhou 510623,China; 2. State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400030,China);Sensitivity Analysis of HVDC Transmission System Reliability Using the Least Square Method[J];Automation of Electric Power Systems;2009-18
9 He Jianjun Ren Zhen Wang Guanjie Yang Hao Huang Wenying (Chongqing University) (South China University of Technology);Stepwlse FD Method for Reliability Evaluation of Substation Bus Arrangement[J];PROCEEDINGS OF THE CSU-EPSA;1998-01
10 REN Zhen,WAN Guo cheng (Electrical Power College,South China University of Technology,Guangzhou 510640,China);Research on Mathematic Model of HVDC Transmission System Optical Components[J];Electric Power Automation Equipment;2002-02
China Proceedings of conference Full-text Database 2 Hits
1 Dongsong YAN,Yuanliang HUANG Electric Automatization Institute of Jinan University,Zhuhai of Guangdong,China;Simulation Analysis Based on Fault Tree for Traction Substation SCADA[A];[C];2011
2 CHENG Hongbo;HE Zhengyou;MU Xiuqing;School of Electrical and Electronic Engineering,East China Jitaotong University;School of Electrical Engineering,Southwest Jiaotong University;;Health Monitoring and Evaluation of Traction Power Supply System for High-Speed Railway Based on Multi-Layer Immune Model[A];[C];2013
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 WANG Yu Shanxi Jinshan Magnetic Material Co, Ltd, Taiyuan 030024, China;Calculation of Magnetic Force of Permanent Magnet Devices[J];Journal of Magnetic Materials and Devices;2007-05
2 WANG Zheng,XIE Li-yang,LI Bing (School of Mechanical Engineering & Automation,Northeastern University,Shenyang 110004,China.);Reliability Model of Failure-Dependent System with Frequency of Loading Taken into Account[J];Journal of Northeastern University(Natural Science);2007-05
3 XIAO Li-ye1,2,LIN Liang-zhen1,2,XU Ming-ming1,2,DAI Shao-tao1,2(1.Key Laboratory of Applied Superconductivity,Chinese Academy of Sciences,Beijing 100190,China; 2.Institute of Electrical Engineering,Chinese Academy of Sciences,Beijing 100190,China);Future power grid — Multiple-level DC loop grid and "Cloud Powering"[J];Advanced Technology of Electrical Engineering and Energy;2011-04
4 Tian Lulin1 Jia Rong1 Yang Guoqing1 Tian Qi2 Li Zhihang3 Li Hui1 (1. Xi’an University of Technology Xi’an 710048 China 2. Northwest University Xi’an 710069 China 3. Xidian University Xi’an 710071 China);The Magnetic Field and Magnetic Force of Permanent Magnet Affixed to a Plane Magnetizer[J];Transactions of China Electrotechnical Society;2008-06
5 Zhang Jing1 Xu Zheng1 Chen Hairong2 (1. Zhejiang University Hangzhou 310027 China 2. JinHua College of Profession and Technology Jinhua 321017 China);Startup Procedures for the VSC-HVDC System[J];Transactions of China Electrotechnical Society;2009-09
6 Xie Kaigui1 Wu Tao1 Huang Ying2 Jian Hongyu3 Hu Bo1 Li Xiaolin2 Wang Libin1 (1.State Key Laboratory of Power Transmission Equipment and System Security and New Technology Chongqing University Chongqing 400044 China 2.China Southern Power Grid Technology Research Center Guangzhou 510623 China 3.China Southern Power Grid EHV Power Transmission Company Guangzhou 510620 China);Reliability Optimal Distribution for HVDC Systems Using Bisection Method[J];Transactions of China Electrotechnical Society;2010-05
7 Chen Xia1 Lin Weixing1 Sun Haishun1 Wen Jinyu1 Li Naihu2 Yao Liangzhong3 (1.State Key Laboratory of Advanced Electromagnetic and Technology Huazhong University of Science and Technology Wuhan 430074 China 2.ALSTOM Grid Technology Center(China) Co.Ltd Shanghai 201114 China 3.ALSTOM Grid Research & Technology Center Stafford ST174LX United Kingdom);LCC-MTDC Technology for Wind Farms Integration[J];Transactions of China Electrotechnical Society;2011-07
8 Chen Weijun (Chongqing University);Ultra HVDC Converter System Reliability Evaluation[J];Electrotechnical Application;2007-12
9 SUI Xin-xian,WANG Qian,YANG Ya-qiang(School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China);Study on Impact of Distributed Generation on Distribution System Reliability[J];Journal of Electric Power;2010-01
10 SHEN Wei-hua, LI Xue-peng, HU Ming, MENG Xuan, XU Yu-xiang, LI Wei-da, XUE Qin (Northwest Electric Power Design Institute, Xian710032,China);DC Power Transmission System Reliability Specifications and Measures of Increasing Reliability[J];Electric Power Construction;2007-02
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 LI Feng-qi,YU Ke-wu,SHE Zhen-qiu,CHANG Nai-chao (Grid Operation Branch of SGCC,Beijing 100005,China);Fault Analysis and Trouble-Shooting of Control and Protection System in Three Gorges HVDC Transmission Project[J];Electric Power Construction;2010-05
2 RUAN Siye1,XU Zhiqiang2 (1. Grid Operation Branch of SGCC, Beijing 100052,China; 2. Beijing Electric Power Transmission and Transformation Company, Beijing 102401, China);Action Analysis of Non-electrical Protection for Converter Transformer and Smoothing Reactor[J];Electric Power Construction;2011-12
3 ZHANG Peng,LIU Sen,LEI Bing,HE Runhua (China Southern Grid EHV Power Transmission Company,Guangzhou 510405,China);A Novel Reliability Index for HVDC Transmission System[J];Automation of Electric Power Systems;2011-12
4 LIANG Xu-ming,WANG Yue,JIANG Sheng,WANG Kun(Grid Operation Branch of State Grid Corporation of China,Dongcheng District,Beijing 100005,China);Analysis on Power Consumption and Losses of HVDC Power Transmission Systems of State Grid Corporation of China[J];Power System Technology;2009-19
5 ZHANG Hai-yan,CHANG Yong,SHAN Hua-ping(State Grid Operation Co., Ltd.,Dongcheng District,Beijing 100005,China);Summarization of Converter Transformer Operation and Maintenance of EHVDC Power Transmission Systems[J];Power System Technology;2009-19
6 LI Zhiyong1,ZHANG Guohua1,ZHANG Guowei2,XU Lingling2 (1.State Grid Operation Company,Xuanwu District,Beijing 100052,China;2.State Grid Corporation of China,Xicheng District,Beijing 100031,China);Analysis on Reliability of HVDC Power Transmission Systems of State Grid Corporation of China in 2009[J];Power System Technology;2010-11
7 ZHENG Chuancai1,GUAN Lin2(1.Guangzhou Power Supply Bureau,Guangzhou 510620,Guangdong Province,China; 2.School of Electric Power,South China University of Technology,Guangzhou 510640,Guangdong Province,China);Assessment on Fault Characteristics of Yunnan to Guangdong UHVDC Transmission and The Influence of Forced Outage on Power System at Receiving End[J];Power System Technology;2012-01
8 ZHANG Ying1,TAI Nengling1,XU Bin2(1.School of Electronic Information and Electrical Engineering,Shanghai Jiao Tong University,Shanghai 200240,China; 2.NARI-Relays Electric Co.Ltd.,Nanjing 211102,China);Travelling Wave Based Pilot Directional Protection for HVDC Line[J];Automation of Electric Power Systems;2012-21
9 WEI Jie1,GAO Haifeng1,HUANG Ruiping1,SU Zhiyi1,SHAAN Huaping2(1.China Electric Power Research Institute,Haidian District,Beijing 100192,China;2.State Grid Operation Company,Dongcheng District,Beijing 100004,China);Analysis and Countermeasure on Typical External Insulation Failure of Main Equipments of ±500 kV Converter Stations[J];Power System Technology;2012-12
10 WANG Yong1,HAN Xueshan1,DING Ying2,SHEN Jie3(1.Key Laboratory of Power System Intelligent Dispatch and Control(Shandong University),Ministry of Education,Jinan 250061,Shandong Province,China;2.State Grid of China Technology College,Jinan 250002,Shandong Province,China; 3.Shandong Liaocheng Power Supply Company,Liaocheng 252000,Shandong Province,China);Markov Chain-Based Rapid Assessment on Operational Reliability of Power Grid[J];Power System Technology;2013-02
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Ren Zhen, Wu Juan (South China University of Technology. 510641, Guangzhou, China)Chen Lifang (Electricity Overhaul Company of the Pearl River, 511458, Guangzhou. China);EQUIVALENT MODEL FOR HVDC RELIABILITY EVALUATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-09
2 ILren Fushuan, A. K. David(1. Zhejiang University. Hangzhou 310027. China)(2. The Hong Kong Polytechnic University. Hong Kong. China);BIDDING STRATEGIES IN ELECTRICITY MARKETS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-14
3 Ren Zhen1 ,Wu Jiekang1 ,Wu Zhongmin2 1.South China U niversity of Technology,Guangzhou5 10 6 40 ,China 2 .Guangdong Electric Power Group Corp,Guangzhou 5 10 6 0 0 ,China;CONGESTION MANAGEMENT AND PRICING IN COMPETITIVE POWER MARKET[J];Automation of Electric Power Systems;2001-02
4 Cheng Lin,Guo Yongji Tsinghua University,Beijing 10 0 0 84,China;NEW ALGORITHM OF ADEQUACY AND SECURITY EVALUATION FOR BULK POWER SYSTEM[J];Automation of Electric Power Systems;2001-19
5 Ma L i1 ,Wen Fushuan2 ,A.K.David3 1.Zhejiang U niversity,Hangzhou 310 0 2 7,China 2 .The University of Hong Kong,Hong Kong,China 3.Hong Kong Polytechnic University,Hong Kong,China;A PRELIMINARY INVESTIGATION ON BIDDING STRATEGIES EMPLOYING STEP-WISE BIDDING RULES[J];Automation of Electric Power Systems;2002-09
6 Dai Yan1 ,H an Zhenxiang2 ,L ou Wei3 1.Zhejiang Electric Power Dispatching and Com munication Center,Hangzhou310 0 0 7,China 2 . Zhejiang U niversity,Hangzhou 310 0 2 7,China 3.Hangzhou Electric Automation Institute,Hangzhou310 0 0 9,China;PRICE BIDDING ANALYSISIN ZHEJIANG ELECTRICITY MARKET[J];Automation of Electric Power Systems;2002-09
7 Ren Zhen 1, Wan Guanquan 1, Huang Jinfeng 1, Huang Wenying 1, Gao Zhihua 2 (1. South China University of Technology, Guangzhou 510640, China) (2. Guangdong Province Power Dispatching Center, Guangzhou 510600, China);PREDICTION OF ORIGINAL RELIABILITY PARAMETER OF POWER SYSTEMS BY AN IMPROVED GREY MODEL[J];Automation of Electric Power Systems;2003-04
8 LU Ning (Plan Department of Shenzhen Power Supply Bureau,Shenzhen 528001,China);Measurement and calculation about the integrated automation of transformer substation[J];Telecommunications For Electric Power System;2001-07
9 REN Zhen,WAN Guo cheng (Electrical Power College,South China University of Technology,Guangzhou 510640,China);Research on Mathematic Model of HVDC Transmission System Optical Components[J];Electric Power Automation Equipment;2002-02
10 REN Zhen 1, HE Jian jun 2, CHEN Jun 3, HUANG Wen ying 1, LI Ben he 4 (1. South China University of Technology, Guangzhou 510641, China; 2. Chongqing Electric Power Bureau, Chongqing 400014, China; 3. South Electric Power Company, Guangzhou 510;MONTE CARLO-FD COMPREHENSIVE METHOD FOR RELIABILITY EVALUATION OF AC/DC HYBRID NETWORK SYSTEMS[J];POWER SYSTEM TECHNOLOGY;2000-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved