Selection of Turbine-generator Unit and Its Parameters for Stung Cheay Areng Hydropower Station

XIONG Xiao-ming,CHEN Lian(Guangxi Electric Power Industry Investigation Design and Research Institute,Nanning 530023)  
In order to rationally select type and parameters of turbine-generator unit for Stung Cheay Areng hydropower station,a series of schemes are compared,and technical economic analysis is made based on basic parameters of the station.It is determined that the station shall be equipped with three Francis turbine generator units with an installed capacity of 108MW,and the runner diameter of the turbine is 1.9m.
【CateGory Index】: TV734