Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Infrared Technology》 1993-06
Add to Favorite Get Latest Update

Effect of the Medium in Radiation Transmitting Path on Single-band Infrared Themometry

Jiang Shichang (Shanghai Institute of Process Automation Instrumentation, Shanghai, 200233)  
Effects of the medium in radiation transmitting path onsingle-band infrared thermometry have been analysed. Considering the "equivalent affection factor of the me dium", i.e. the difference between the spectrum of measured objects and the spectrum response of radiation thermometers, error equations relative to the limiting effective wave length of radiation thermometers are deduced. Curves of measurement values vs the real temperatures of measured objects are presented. A method of eliminating the medium effect by measuring medium affection factor of the infrared thermometer in situ has been proposed.
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 TAN Xin quan, MEI Xiao ying, SUN Hai wei, XU Sheng hui (Dept. of Electronic & Information Engineering, Huazhong Univ. of Sci. & Tech., Wuhan 430074, China);Hardware design of the real time acquisition for a color image[J];OPTICAL TECHNOLOGY;1999-06
2 SHI De heng, CHEN Yu ke (Department of Foundation, the First Aeronautical College of Air Force, Xinyang 464000, China);Precise measurement instrument for temperature and specific radiance of high temperature object using laser and standard heat noise radiating source and 8031 chip microprocessor[J];OPTICAL TECHNOLOGY;1999-06
3 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1. Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2. Henan Normal University, Xinxiang 453002, China);An IR colorimeter using pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-05
4 SHI De heng, CHEN Yu ke (The First Aeronautical College of Air Force, Xinyang 464000, China);System for precisely measuring temperature and radiativity of high temperature object[J];OPTICAL TECHNOLOGY;1999-03
5 SUN Hong bing 1, DING Wan shan 2(1. Department of Physics, HuaiYing Teachers College, Huaian 223001, Jiangsu, China) (2. College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, Jiangsu, China);The Real-time Temperature Measurement System of High Temperature Flames Based on Laser Diagnosis Technology[J];Journal of Huaiyin Teachers College;2002-03
6 ;High-Temperature Measurement System in Real time Using Chip Microprocessor and it's Measurement Precision Analyse[J];LASER & INFRARED;1999-06
7 Shi Deheng (Dept.of Foundation,The First Aeronautical College of Air Force,Xinyang 464000) Chen Anjun (Dept.of Physics,Xinyang Teachers College,Xinyang 464000);An intelligent measurement instrument of specific radiance of high temperature object using laser in real time[J];LASER JOURNAL;1998-06
8 Shi Deheng;Zhang Yunlong;Huang Yijun;Xu Qifu (The First Aeronautical College of Air Force,Xinyang, 464000);A Study of the On-line Measuring Instrument for the Specific Radiance of High-temperature Object[J];CHINESE JOURNAL OF SCIENTIFIC INSTRUMENT;1999-04
9 Shi Deheng 1 Xu Qifu 1 Chen Yuke 2 Liu Yufang 1 (Dep. of Foundation The First Aeronautical College of Air Force, Xinyang Henan 464000,China) 2 (Department of Physics, Henan Normal University, Xinxiang, Henan 453002);A Study of the On-line Measuring Instrument for Temperature of High-temperature Object[J];Chinese Journal of Scientific Instrument;2001-03
10 Jiang Shichang;The Infrared Measuring Technology for Temperature[J];Process Automation Instrumentation;1996-04
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 XIONG Ping (Chongqing Optoelectronics Research Institute, Chongqing 400060, CHN);Comparison of CCD and CMOS Image Sensors[J];Semiconductor Optoelectronics;2004-01
2 ;The Present Development And Status Of Infrared Focus Plane Array Technology[J];Sensor World;2005-05
3 Zhu Tao; Han Gaorong; Ding Zishang (Zhejiang University);Progress in Ceramics of Infrared Pyroelectric Detectors[J];MATERIALS SCIENCE AND ENGINEERING;1995-03
4 WANG Hong1,PENG Liang2,YU Zong-guang 2(1.China Electronic Technology Group Corporation,Department of basic products,Beijing,100846,China;2.China Electronic Technology Group Corporation,No.58 Research Institute,Wuxi 214035,China);The Actuality and Development Directions of FPGA[J];Electronics & Packaging;2007-07
5 Shao Dan Dai Mingyuan(Tongji University,Shanghai 200092);Design of traffic monitoring system of speedway based on linear CCD[J];Electronic Measurement Technology;2007-02
6 Deng Xingzhong ;Yang Zifang; Liu Bo(Huazhong University of Science and Technology);Measure on Improving Sampling Precision of the Optic Fiber Intelligent Colorimetric Thermometer[J];Journal of Electronic Measurement and Instroment;1995-02
7 Guo Limin Chen Ning Liu Honggang Zhang Xiangdong (School of Telecommunication Engineering,Xidian University,Xi'an 710071,China);Implementation of Video Capture Based on DirectShow Technology[J];Electronic Science and Technology;2007-02
8 YAO Yue-song1,FAN Xiang2,LI Fei1,ZHU Bin1(1.Electronic Engineering Institute,Hefei 230037,China;2.University of Science and Technology of China,Hefei 230027,China);High Reflectivity Metal Mirror for 1.06 μm Laser[J];Electro-Optic Technology Application;2007-01
9 WANG Hai-tao, ZHANG Guo-qiang, ZHANG Rong-wen (Element 230 of Unit 91550,Dalian 116023,China );Application of optical fiber transmission in miss distance measure system[J];Optical Communication Technology;2007-02
10 LIN Jia ming 1, YANG Long rong 2 (1 Beijing institute of technology, Beijing 100081, China) (2 Taiwan Mintron Enterprise Co., Ltd., China);Development tendency and application prospects of CCD camera technique[J];OPTICAL TECHNOLOGY;1999-06
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 Jiang Yalong, Yuan Hongyong (State Key Laboratory of Fire Science, USTC, Heifei 230027, China)[;The Application of Temperature measurement By CCD to Modern Coking-Furnace[J];Engineering Science;2003-04
2 FU Tai-ran1, CHENG Xiao-fang2, ZHONG Mao-hua1, YANG Zang-jian21. China Academy of Safety Science & Technology, Beijing 100029, China2. Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230027, China;Analyses of Spectral Emissivity in Radiation Temperature Measurement[J];Spectroscopy and Spectral Analysis;2008-01
3 TAN Xin quan, MEI Xiao ying, SUN Hai wei, XU Sheng hui (Dept. of Electronic & Information Engineering, Huazhong Univ. of Sci. & Tech., Wuhan 430074, China);Hardware design of the real time acquisition for a color image[J];OPTICAL TECHNOLOGY;1999-06
4 SHI De heng, CHEN Yu ke (Department of Foundation, the First Aeronautical College of Air Force, Xinyang 464000, China);Precise measurement instrument for temperature and specific radiance of high temperature object using laser and standard heat noise radiating source and 8031 chip microprocessor[J];OPTICAL TECHNOLOGY;1999-06
5 SHI De heng 1, LIU Yu fang 2, CHEN Yu ke 1 (1. Department of Foundation, the First Aeronautical College of Air Force, Xinyang 464000, China) (2. Department of Physics, Henan Normal University, Xinxiang 453002, China);Precise measurement instrument for temperature and specific radiance using lasers and pyroelectric detector in real-time[J];OPTICAL TECHNOLOGY;2000-02
6 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1. Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2. Henan Normal University, Xinxiang 453002, China);An IR colorimeter using pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-05
7 SHI De heng 1, LIU Xin jian 2, XU Qi fu 1, CHEN Yu ke 1, LIU Yu fang 3 (1 Deparment of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Xinyang College of Education, Xinyang 464000;Analyses of sensitivity about temperature real-time measurement system using lasers and pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-06
8 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1 Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Henan Normal University, Xinxiang 453002, China);Optimization about temperature real-time measurement system using lasers and pyroelectric detector[J];Optical Technology;2001-02
9 LIU Yu-fang~1, ZHU Zun-lue~1, SHI De-heng~(1,2), SUN Jin-feng~1, CHEN Yu-ke~2(1. College of Physics and Information Engineering,Henan Normal University,Xinxiang453007,China)(2. Department of Foundation, The First Aeronautical College of Air Force, Xinyang464000, China);Optimal design of working wavelength and its bandwidth of a dual-wavelength fiber-optic colorimeter[J];Optical Technique;2005-01
10 LI Zhen-xin~(1,2),SHI De-heng~3,LI Shi-pu~1 (1.Biomedical Materials and Engineering Centre,Wuhan University of Technology, Wuhan 430070,China) (2.Department of Life Science and Technology,Xinxiang Medical College,Xinxiang 453003,China) (3.Department of Physics,Henan Normal University,Xinxiang 453007,China);A temperature measurement system based on liquid crystal valve modulation[J];Optical Technique;2006-03
China Proceedings of conference Full-text Database 1 Hits
1 Wang Yutian Zhao Xiaolong(Electrical Engineering Institute Of Yan Shan University,Qin Huangdao,066004);The Optimized Design to The Wave Length and Band Width of Two-colour Optical Fiber Radiation Pyrometer[A];[C];2007
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved