Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Infrared Technology》 2008-01
Add to Favorite Get Latest Update

Development of Optical Fiber Twenty-Spectral Radiation Pyrometer

XIN Chun-suo DAI Jing-min WANG Ying-li (Dept.of Automation Measurement & Control,Harbin Institute of Technology,Harbin Heilongjiang 150001,China)  
Based on the multi-spectral temperature measurement theory,a twenty-wavelength optical fiber radiation thermometer is developed.The true temperature and the multi-wavelength normal spectral emissivity of the specimen are measured by a multi-wavelength pyrometer.It transfers optical signal from optical detectors through optical fiber,and this design can enhance convenience for measurement and flexibility for rigorous environment.Rigid design of automatic conversion circuit extends temperature range, and improves precision at the same time.With a mini-controller,it realizes auto-operation and cooperation with other devices.The system's measured temperature range is from 800 to 3500~C,and corresponding accuracy is less then 1%.
【Fund】: 航天材料及工艺研究所专项基金
【CateGory Index】: TH811
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 6 Hits
1 SUN Xiao gang, HU Xiao guang, DAI Jing min, CONG Da cheng (Dept of Automation Measurement & Control, Harbin Institute of Technology, Harbin 150001, China);Eight-wavelength pyrometer which can simultaneously measure the true temperature and spectral emissivity[J];Optical Technology;2001-04
2 FAN Yi LI Cheng Wei CHU Zai Xiang (Department of Automation Measurement and Control Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China);DEVELOPMENT OF A MILLISECOND PULSE-HEATING APPARATUS WITH A MULTI-WAVELENGTH PYROMETER AND AN INTEGRATING REFLECTOMETER FOR THERMOPHYSICAL PROPERTIES MEASUREMENT[J];Journal of Infrared and Millimeter Waves;2002-03
3 Dai Jingmin; Yang Maohua; Chu Zaixiang (Precise Instruments Department, Harbin Institute of Technology, Harbin, Hrilongjiang, 150001, China );MULTI-WAVELENGTH PYROMETER AND ITS APPLICATIONS[J];JOURNAL OF INFRARED AND MILLIMETER WAVES;1995-06
4 Dai Jingmin, Yang Maohua, Chu Zaixiang (School of Mechatronic Engineening, Harbin Institute of Technology, Harbin 15001);One-Point Calibration Technique of Pyrometer on the Basis of Wavelength Function Measurement and Error Checks[J];Acta Metrologica Sinica;1999-01
5 Yu Lunpeng;Peng Ruixin;A new method for selecting radiation pyrometer ' s working wavelength[J];Journal of Astronautic Metrology and Measurement;1998-02
6 DAI Jing_min(Harbin Institute of Technology,Harbin 150001,China);Survey of Radiation Thermometry[J];Techniques of Automation and Applications;2004-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LIU Qing-ming,BAI Chun-hua(School of Aerospace Science and Engineering,Beijing Institute of Technology,Beijing 100081,China);Research on the Explosive Temperature Response of Fuel Air Explosive Measured by Colorimetric Thermometer[J];Acta Armamentarii;2009-04
2 XIN Chunsuo1,DAI Jingmin1,ZHANG Hu1,HE Xiaowa2 (1.Institute of Automatic Detecting & Process Control System,Harbin Institute of Technology,Harbin 150001,China;2.Aerospace Research Institute of Materials and Processing Technology,Beijing 100076,China);A Measuring System for Carbon-Carbon Composite Thermal Physical Properties at High Temperature[J];Journal of Test and Measurement Technology;2008-05
3 XIN Chunsuo1,DAI Jingmin1,ZHANG Hu1,HE Xiaowa2(1.Institute of Automatic Detecting & Process Control System,Harbin Institute of Technology,Harbin 150001,China;2.Aerospace Research Institute of Materials and Processing Technology,Beijing 100076,China);Measuring Technology of One-Dimensional High Temperature Distribution[J];Journal of Test and Measurement Technology;2009-01
4 He Jin; Sun Xiaogang; Dai Jingmin (Department of Precision Instrument, Harbin Institute of Technology, Harbin 150001 );A new Precise(Standard) Multi-wavelength Photoelectric Pyrometer[J];JOURNAL OF ELECTRONIC MEASUREMENT AND INSTROMENT;1999-02
5 XIAO Peng,SUN Xiao-gang,DAI Jing-min ( Department of Automation Measurement & Control,Harbin Institute of Technology,Harbin 150001,China );Temperature and spectral emissivity measurement of the metallic thermal protection blanket based on multi-wavelength thermometry[J];Opto-Electronic Engineering;2007-08
6 CAI Ru-hua~1,CHEN Guang-sheng~2(1.School of Mathematics and Computational Science,Guilin University of Electronic Technology,Guilin 541004,China;2.School of Applied Computer Science,Hechi Vocational College,Hechi 547000,China);A light frequency equation of inflexion on planck function[J];Journal of Guilin University of Electronic Technology;2006-05
7 WANG Qing-wei,XIAO Peng,SUN Xiao-gang (Dept.Automation Measurement and Control Engineering,Harbin Institute of Technology,Harbin 150001,China);Research on the data processing multispectral method of melting point temperature and normal spectral emissivities[J];Optical Technique;2007-03
8 YANG Hao-lin1,2,ZHAO Dai-qing2,YANG Wei-bin2(1.Department ofThermal Science and Energy Engineering,University of Science and Technology of China,Hefei 230027,China;2.Guangzhou Institute of Energy Conversion under the China Academy of Sciences,Guangzhou 510640,China);The Application of Non-contact Infrared Heating System to Flames Measurement[J];Industrial Heating;2007-01
9 Sun Xiaogang; Dai Jingmin; Lu Xiaodong (Harbin Institute of Technology);THE THEORY OF MULTI-WAVELENGTH THERMOMETRY AND ITS FITING ERROR ESTIMATION[J];NATURAL SCIENCE JOURNAL OF HARBIN NORMAL UNIVERSITY;1997-04
10 XU Xue zhong 1,2 , WEI Hai ying 2, XIAO Chang yan 2, GU Ping an 2 (1.Nanjing University of Science and Technology, Nanjing 210094; 2.Northwest Institute of Nuclear Technology, Xian 710024);The Thermal Radiation of Fuel air Mixtures with Single event Ignition[J];;1999-04
【Secondary Citations】
Chinese Journal Full-text Database 8 Hits
1 DAI Jing Min LU Xiao Dong CHU Zai Xiang KANG Song Gao FAN Chuan Xin  (Department of Automatic Measurement and Control, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China);DEVELOPMENT OF MULTI-POINT MULTI-WAVELENGTH PYROMETER WITH A SYNCHRONOUS DAS[J];JOURNAL OF INFRARED AND MILLIMETER WAVES;2000-01
2 CONG Da Cheng DAI Jing Min SUN Xiao Gang CHU Zai Xiang (School of Computer Science and Electric Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China);STUDY OF THE APPLICATION OF RBF NETWORK TO MULTI-SPECTRAL THERMOMETRY[J];Journal of Infrared and Millimeter Waves;2001-02
3 Dai Jingmin; Yang Maohua; Chu Zaixiang (Precise Instruments Department, Harbin Institute of Technology, Harbin, Hrilongjiang, 150001, China );MULTI-WAVELENGTH PYROMETER AND ITS APPLICATIONS[J];JOURNAL OF INFRARED AND MILLIMETER WAVES;1995-06
4 SUN XiaoGang DAI JingMin CONG DaCheng CHU ZaiXiang(Department of Precise Instrument, Harbin Institute of Technology, Harbin, Heilongjiang 150001,China);THEORETICAL STUDY OF MULTIWAVELENGTHRADIATION THERMOMETRY——Autosearch for Emissivity Expression General[J];JOURNAL OF INFRARED AND MILLIMETER WAVES;1998-03
5 SUN Xiao gang, DAI Jing min, CHU Zai xiang (Harbin Institute of Technology, Harbin 150001, China);Study of Multispectral Thermometry by Artificial Neural Network[J];Acta Metrologica Sinica;2001-01
6 DAI Jing min, FAN Yi, CHU Zai xiang (Department of Automatic Measurement and Control, Harbin Institute of Technology, Harbin 150001, China);Reviews of Pulse-heating Technique for Thermophysical Properties Measurement[J];Acta Metrologica Sinica;2001-04
7 SUN Xiaogang, DAI Jingmin, CONG Dacheng, CHU Zaixiang(Department of Automation Measurement and Co ntrol, Harbin Institute of Technology, Harbin 150001, China);Plume temperature measurement of a solid propellant ro cket engine using multispectral thermometry[J];Journal of Tsinghua University(Science and Technology);2003-07
8 Dai Jingmin Shi Yiguo Kang Weimin (Department of Precise Instruments, Harbin Institute of Technology, 150001) Dong Linsheng Cao Ying Li Yinxian (Institute No 44 of the Ministry of Aerospace Industry, Xi'an, 710000);TRUE TEMPERATURE MEASUREMENT OF ABLATIVE MATERIALS USING MULTISPECTRAL THERMOMETRY[J];JOURNAL OF ASTRONAUTICS;1996-03