Numerical Research on Plume Infrared Radiation of Helicopter Exhaust System

MA Geng-jun;ZHANG Yun-fei;School of Aeronautic Science and Engineering,Beijing University of Aeronautics and Astronautics;  
Plume is one of main radiation sources of helicopter exhaust system. A numerical method of helicopter plume infrared radiation was developed, which combined radiative transfer equation(RTE) with plume flow field model and exponential wide band model(EWBM) of gas radiation. Two computation cases were used to test the method from different aspects, which confirmed that the method is feasible for computation and analysis of plume infrared radiation, and can meet the requirement of engineering design.
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.