Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Power System Protection and Control》 2015-05
Add to Favorite Get Latest Update

Research on APF based on vector decoupling control and predictive current control

BAO Lushan;WANG Yifei;LI Yan;College of Electrical Engineering, Southwest Jiaotong University;  
Because the ip-iq harmonic detection algorithm based on instantaneous reactive theory cannot detection reactive current under nonideal power grid voltage, this paper presents the operation mechanism of the shunt active filter with a new control algorithm. The control algorithm is composed of indirect current loop for active and reactive power control and predictive current loop for harmonic filtering control. Due to the parameters of inductor change, the value along with the current will produce error, so a decoupling controller based on synthetic vector is put forward to overcome the defect and improve the anti-interference ability of the system. The simulation is verified to the control strategy by Matlab/Simulink. The results show the correctness and effectiveness.
【CateGory Index】: TM761
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 9 Hits
1 Quan Hengli1 Liu Zhigang1 Zhang Gang2 Wu Zuomin1(1.Beijing Jiaotong University Beijing 100044 China 2.Tsinghua University Beijing 100084 China);Design of Main Circuit's Key Parameters on Shunt Active Power Filters[J];Transactions of China Electrotechnical Society;2011-12
2 ZENG Fan-peng,WANG Jian-ze,FU Xiang-yun,TAN Guang-hui,JI Yan-chao (School of Electrical Engineering and Automation,Harbin Institute of Technology,Harbin 150001,Heilongjiang Province,China);A Simple Control Method of Active Power Filter in Synchronous Rotating Reference Orthogonal Coordinate System[J];Power System Technology;2006-18
3 Sun Xiaofeng Zeng Jian Li Ningning Li Xin(Key Lab of Power Electronics for Energy Conservation and Motor Drive of Hebei Province Yanshan University Qinhuangdao 066004 China);Improvement for the Closed-Loop Control of Shunt Active Power Filter Based on Feedback of Supply-Side Current[J];Transactions of China Electrotechnical Society;2012-10
4 CHEN Yang,WANG Hai-xin,ZHU Yuan-fu,HUANG Hai-hong (Hefei University of Technology,Hefei 230009,China);Study of Voltage PWM Rectifier Based on Variable Parameters PI[J];Power Electronics;2012-11
5 Cao Wu;Zhao Jianfeng;Jiang Nan;School of Electrical Engineering, Southeast University;;A New Space Vector Hysteresis Current Control Scheme Based on Synchronous Reference Frame for APF[J];Transactions of China Electrotechnical Society;2013-12
6 HU Yongyin;LI Xingyuan;ZHOU Hongyu;LI Kuan;GU Chao;School of Electrical Engineering and Information,Sichuan University;Dadu River Hydropower Development Co.,Ltd.;School of Electrical Engineering and Information,Xihua University;;A Kind of Harmonic Suppression Controller Used in VSC-HVDC Transmission System[J];Power System Technology;2014-03
7 WANG Hui,DUAN Yu-bing,GONG Yu-lei,LI Qing-min(School of Electrical Engineering,Shandong University,Jinan 250061,China);A decoupling discrete-time control methodology applied to shunt active power filter[J];Power System Protection and Control;2010-11
8 ZHANG Xiao1,KONG Ling-jun1,2,SUN Hua1,2,ZHANG Ke1,2(1.China University of Mining and Technology,Xuzhou 221008,China;2.Jiangsu Electrical Drive & Control Engineering Technology Research Center,Xuzhou 221008,China);The quasi-sliding mode control of the shunt active power filter in three-phase three-wire system[J];Power System Protection and Control;2011-21
9 HUANG Wei1,ZHOU Li-dan2,ZHENG Yi-hui1,WANG Xin1,LI Li-xue1, GAO Ming-shi3,WANG Shu-chun3(1.Center of Electrical & Electronic Technology,Shanghai Jiao Tong University,Shanghai 200240,China; 2.Department of Electrical Engineering,Shanghai Jiao Tong University,Shanghai 200240,China; 3.Songyuan Power Supply Company,Jilin Electric Power Co.,Ltd,Songyuan 138000,China);Neural network PI pepetitive controller for three-phase three-wire shunt active power filter[J];Power System Protection and Control;2012-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 GOU Songbo1,WANG Zhen2,LIU Weibo3 (1. Shengli Oil Field Power Management Company,Dongying 257000,China; 2. Harbin Institute of Technology at Weihai,Weihai 264209,China; 3. Guodian Nanjing Automation Co.,Ltd.,Nanjing 210003,China);APF parallel operation based on d-q transform[J];Electric Power Automation Equipment;2008-03
2 ZHANG Guoxin~1 DING Zujun~2 1.Guodian Nanjing Automation Co.,Ltd.,Nanjing 210003,China; 2.Southeast University,Nanjing 210096,China;Application and improvement of space vector control strategy in APF[J];Electric Power Automation Equipment;2008-12
3 ZHANG Shao-ru1,WU Ai-guo1,GE Yan-rong2,DU Chun-yan1,ZHANG Xue-hui3,QU Bing-feng3 (1.School of Electrical Engineering & Automation,Tianjin University,Nankai District,Tianjin 300072,China; 2.College of Physics and Information Engineering,Hebei Normal University,Shijiazhuang 050016,Hebei Province,China; 3.School of Electrical Engineering & Automation,Hebei University of Technology,Hongqiao District,Tianjin 300130,China);Simple Adaptive Control of DC Voltage in Shunt Active Power Filter[J];Power System Technology;2007-17
4 Zhao Guopeng1 Han Minxiao1,2 Liu Jinjun3(1.North China Electric Power University Beijing 102206 China 2.National State Key Laboratory of New Energy Power System Beijing 102206 China 3.Xi'an Jiaotong University Xi'an 710049 China);Design of Parameters in Static Synchronous Compensator with Indirect Current Control Based on the System Stability[J];Transactions of China Electrotechnical Society;2012-09
5 DING Zujun,LIU Baolian,ZHANG Yulin(Faculty of Electronic and Electrical Engineering,Huaiyin Institute of Technology,Huai’an 223003,Jiangsu Province,China);Optimal Control for DC Side Voltage of Active Power Filter Based on Auto-Disturbance Rejection Control[J];Power System Technology;2013-07
6 ZHOU Erbiao1,CHAO Qin1,CHANG Xiqiang2,ZHANG Yanli3, LIU Defu2,LIU Chuang1,WU Maoqian4(1.College of Electrical Engineering,Xinjiang University,Urumqi 830047,China; 2.Dispatching and Communication Center of Xinjiang Electric Power Company,Urumqi 830002,China; 3.Hami Power Supply Company,Hami 839000,China; 4.Kuitun Power Supply Company,Kuitun 833200,China);Research on Control Strategy of Three Phase Photovoltaic Grid-Connected Inverter[J];Low Voltage Apparatus;2013-06
7 MEI Hongming,WANG Yi,LIU Jianzheng(State Key Lab of Control and Simulation of Power Systems and Generation Equipments(Dept.of Electrical Engineering,Tsinghua University),Haidian District,Beijing 100084,China);A Comprehensive Power Quality Compensation Method Based on Feedback Control of Grid-Side Current[J];Power System Technology;2013-08
8 TIAN Mingxing;YANG Xuesong;YAN Hong;ZHANG Junqiang;College of Automation and Electrical Engineering,Lanzhou Jiaotong University;;Formulae for calculating rated AC inductance of shunt active power filter based on harmonic characteristics of load current[J];Electric Power Automation Equipment;2013-10
9 Chen Zhong;Wang Zhihui;Chen Miao;Nanjing University of Aeronautics and Astronautics Jiangsu Key Laboratory of New Energy Generation and Power Conversion;;High Performance Five-Level Active Filter Applicable to Variable Frequency Aircraft Grid and Its control[J];Transactions of China Electrotechnical Society;2013-12
10 ZHU Ruike;LI Xingyuan;YING Dali;School of Electrical Engineering and Information,Sichuan University;Institute of Logistics Engineering of PLA;;A Frequency Stability Control Strategy for Interconnected VSC-MTDC Transmission System[J];Power System Technology;2014-10
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Tong Mei Xiang Ji(Zhejiang University 310027 China);Variable Structure Control for a Hybrid Power Filter[J];Transactions of China Electrotechnical Society;2002-01
2 Yang Xu Wang Zhaoan (Xi'an Jiaotong University 710049 China);A Novel Quasi-Constant Hysteretic PWM Current Mode Control Approach[J];Transactions of China Electrotechnical Society;2003-03
3 Zhong Yanping (Air Force Radar Academy Wuhan 430019 China);Novel Current Decoupled Control Strategy for PWM Rectifier[J];Transactions of China Electrotechnical Society;2005-08
4 Geng Pan Dai Ke Wei Xueliang Zhang Kai Kang Yong (Huazhong University of Science and Technology Wuhan 430074 China);The Repetitive Control Algorithm Based Current Waveform Correction for Shunt Active Power Filter[J];Transactions of China Electrotechnical Society;2007-02
5 Yan Xiaoqing Yang Jun Wang Zhaoan(Xi'anJiaotong University);The Mathematical Model and Stability Analysis of Shunt Active Power Filter[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1998-01
6 Liu Jinjun Wang Zhaoan(Xi′an Jiaotong University);Uniform Mathematical Description of Instantaneous Reactive Power Theory and Conventional Power Theory and Its Physical Meaning[J];Transactions of China Electrotechnical Society;1998-06
7 ZHOU Wei-ping,WU Zheng-guo,XIA li,LIU Jian-bao(College of Electrical & Information Engineering,Naval University of Engineering,Wuhan 430033,China);A three-phase three-wire active power filter based on DSP and sliding mode control strategy[J];Electric Machines and Control;2006-02
8 LIU Pei guo, DAI Ke, XIONG Jian, CHEN Jian (Huazhong University of Science and Technology, Wuhan 430074, China);A Current Control Technology of Three-phase VSC based on DSP[J];Power Electronics;2003-03
9 YI Ying-ping1, XU Yong1, YAO Wei-zhen2(1.Hunan University, Changsha 410082, China; 2.Xuji Power Ltd., Xuchang 461000, China);Design of Three Phase Large Capacity PWM Rectifier for UPS[J];Power Electronics;2004-02
10 LI Gang1, LUO An2, FU Qing1, TANG Xin1 (1.Central South University, Changsha 410083, China; 2.Hunan University, Ch angsha 410082, China);Fuzzy-PI Control of a New Hybrid Active Power Filter[J];Power Electronics;2005-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved