Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Power System Protection and Control》 2015-05
Add to Favorite Get Latest Update

Design of automatic test system for relay protection device

WANG Zhong;ZHANG Xiaoli;LI Zhongan;LIU Kui;HU Xi;ZHAO Qingchun;Nanjing NARI-Relays Electric Co., Ltd.;China Electric Power Research Institute;  
This paper analyses the status and advantages of automatic test for relay protection device, and describes a set of automatic test system for relay protection device according to the characteristics and requirements of test performance in product development. The distribution architecture and module design concept are adopted by the test system, and a real-time test script is designed based on Python. The test system can realize close loop automatic test and regression test for relays protection device. The system can provide automatic test of relay protection device for conventional substaion or digital substation by modifying its configuration. Each module is described from the aspects of the design explicitly and implementation of test case is emphasized. The proposed system can improve the efficiency and guarantee the quality in practical application of testing process for products development.
【CateGory Index】: TM774
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 LI Zhongan,SHEN Quanrong,WANG Yanguo,LI Xingjian(Nanjing NARI-Relays Electric Co.Ltd.,Nanjing 211102,China);Automated Testing System for IED[J];Automation of Electric Power Systems;2009-08
2 CHEN Zhengming1,CHEN Hui2,CHEN Wei2,XIONG Huaqiang1(1.Jiangxi Electric Power Research Institute,Nanchang 330006,China;2.Electric Power Security and High Efficiency Lab,Huazhong Universityof Science and Technology,Wuhan 430074,China);Test system for complete digital protective relay[J];Electric Power Automation Equipment;2009-05
3 LAI Qing,HUA Jian-wei,L Yun,CHEN Yue-fei,XU Jian (Fujian Electrical Power Testing and Research Institute,Fuzhou 350007,China);Research on general relay protection auto-test system software[J];Power System Protection and Control;2010-03
4 YING Zhan-huang,HU Jian-bin,ZHAO Rui-dong,LI Bao-en (XJ Electric Co.,Ltd,Xuchang 461000,China);Research and design of relay protection equipment automated test system[J];Power System Protection and Control;2010-17
5 WANG Zhi-guo1,LI Xing-jian1,WANG Yan-guo1,SHEN Quan-rong1,QIN Yu-fei2,YU Zhe1,LI Zhong-an1 (1. Nanjing NARI-Relays Electric Co. Ltd,Nanjing 211102,China; 2. School of Control Science and Engineering,North China Electric Power University,Beijing 102206,China);Research on the development of relay protection tester based on unified building mode[J];Power System Protection and Control;2010-19
6 LI Tie-cheng 1,GAO Xiang-jun 2,HAO Xiao-guang 1,ZHANG Li 1,HE Lei 1,GAO Zhi-qiang 1(1. Hebei Electric Power Research Institute,Shijiazhuang 050021,China;2. Shijiazhuang Power Supply Company,Shijiazhuang 050051,China);Research of the test method for digital protection device[J];Power System Protection and Control;2011-03
7 LI Xian-mei1,HUANG Jia-dong1,TANG Bao-feng2(1.North China Electric Power University,Baoding 071003,China; 2.Hebei Electric Power Research Institute,Shijiazhuang 050021,China);Research on testing technology of relay protection for digital substation[J];Power System Protection and Control;2012-03
8 JIANG Chong-wu,LIU Bin,WANG Yi-chen,HU Xuan(Department of System Engineering of Engineering Technology,Beihang University,Beijing 100083);Real-time Embedded Software Test Script Based on Python[J];Computer Engineering;2009-15
9 SONG Li-qun(Dept.of Electric Power Engineering,Nanjing Institute of Technology,Nanjing 210013,China);The Microcomputer-based Protection Tester and Testing Technology[J];Journal of Nanjing Institute of Technology(Natural Science Edition);2006-01
10 HU Zai-chao,YAO Liang,ZHANG Yao(Guodian Nanjing Automation Co.Ltd.,Nanjing 211100,China);Automatic Testing Method of Intelligent Relay Protection Device[J];Jiangsu Electrical Engineering;2013-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LIU Shi-ming1,LI Wei2,YUE Zeng-hui2 (1.School of Electrical Engineering,Shandong University,Jinan 250061,China;2.Yantai Dongfang Electronics Co.LTD,Yantai 264000,China);Software-only testing system for protective relay based on IEC61850[J];Journal of Electric Power Science and Technology;2010-01
2 Peng Huiling(Departmentof Computer and Information Engineering,Luoyang Institute of Science and Technology,Luoyang 471023,China);Research on the Integrate Testing Process of Embedded Software and Hardware[J];Microcontrollers & Embedded Systems;2010-12
3 TIAN Li-ping(School of Electrical and Electronic Engineering,East China Jiaotong University,Nanchang 330013,China);Discussion of 110kV digital substation field test[J];Electronic Instrumentation Customers;2012-04
4 LIU Wei 1,ZHAO Yong 2,SHI Guang 2(1.Henan Electric Power Economic Research Institute of Henan Electric Power Company,Zhengzhou 450052,China;2.Henan Electric Power Research Institute,Zhengzhou 450052,China);One-key test system for relay protection equipment of intelligent substation[J];Electric Power Automation Equipment;2013-02
5 XUE Jian-bin;Zhuhai Power Bureau;;An Isolation Method of Electrical Virtual Circuit in Intelligent Substaion[J];Journal of Jiangxi Vocational and Technical College of Electricity;2013-03
6 GAO Lei;BU Qiang-sheng;LU Wei;XIANG Qian;Jiangsu Electric Power Company Research Institute;Wuhan Zhongyuan Huadian Science and Technology Co Ltd;Ponovo Power Co Ltd;;Research on Key Indexes and Testing Method of IEC61850 Test Equipment for Relay Protection[J];Electrical Measurement & Instrumentation;2013-12
7 LUO Yuesheng;MU Zongjian;JIN Xiaobo;LI Yiquan;XIA Yun;Electric Power Dispatching Control Center of GPGC;North China Electric Power University;Beijing Joint Bright Digital Power Technology Co.,Ltd.;;Definite Value Risk Estimation System for Relay Protection in Grid-involved Power Plant Based on Expert System[J];Guangdong Electric Power;2013-11
8 TANG Hai-guo;LENG Hua;ZHU Ji-ran;GONG Han-yang;Electric Power Research Institute,State Grid Hunan Electric Power Company;;Design of an Intelligent Terminal Communication Module Based on DSP and Ethernet Switch Chip[J];Electric Power Information and Communication Technology;2014-03
9 Tang Ming;Hu Yong;He Xiaopeng;Wu Dongsong;Liu Kailu;Shenzhen Golden Highway Technologies Co.Ltd;;Development of the Conformance Test System for Distribution Automation Equipment Communication Protocol[J];Electrical Engineering;2014-08
10 CHEN Yan-zhang;CEPREI;;Application of Python Language in Software Performance Testing Based on Domestic Operating System[J];Electronic Product Reliability and Environmental Testing;2013-S1
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 LIU Bin (Beijing University of Aeronautics and Astronautics,Dept. of System Engineering of Engineering Technology) GAO Xiao peng (Beijing University of Aeronautics and Astronautics,Dept. of Computer Science and Engineering) LU Min yan RUAN Lian (B;Study on Reliability Simulation Testing System for Embedded Software[J];JOURNAL OF BEIJING UNIVERSITY OF AERONAUTICS AND ASTRONAUTICS;2000-04
2 Zhong Deming Liu Bin Ruan Lian(Dept.of System Engineering of Engineering Technology,Beijing University of Aeronautics and Astronautics,Beijing 100083,China);Research on software architecture of embedded software simulation testing environment[J];Journal of Beijing University of Aeronautics and Astronautics;2005-10
3 Zheng Sanli1 Fan Yu1 Huang Mei1 Jiang Qirong2(1.Beijing Jiaotong University Beijing 100044 China 2.Tsinghua University Beijing 100084 China);Pre-Simulation of PC Based Closed-Loop Testing for Protective Relays[J];Transactions of China Electrotechnical Society;2004-05
4 Ye Lin (China Agricultural University);Real Time Digital Simulator and its Applications[J];Electrotechnical Journal;2004-07
5 Yan Changyou , Li Zhaocheng , Fan Qi , Zhang Tao ( North China Electric Power University, Beijing 102206, China) ( Beijing Sifang Tongchuang Automation Co Ltd, Beijing 100085, China);TESTING SOFTWARE OF A SAMPLING UNIT IN THE DISTRIBUTED PHASOR MONITORING SYSTEM[J];Automation of Electric Power Systems;2004-19
6 LI Guojie ZHANG Dan JI Xina 1.XJ Electric Co Ltd,Xuchang 461000,China Zhou Lianhua 2.XJ Group Co Ltd,Xuchang 461000,China;Development of the Conformance Test System for Substation Equipment Communication Protocol Part One Design and Application[J];Automation of Electric Power Systems;2006-15
7 LI Juan1, JIAO Shaohua2, XIAO Shiwu3(1. Beijing Institute of Machinery, Beijing 100085, China)(2. Beijing Sifang Electric Group Co Ltd, Beijing 100085, China)(3. North China Electric Power University, Beijing 102206, China);A Multi-terminal and Closed-loop Power System Real-time Testing Simulator at Different Substations[J];Automation of Electric Power Systems;2007-10
8 LI Zhongan,SHEN Quanrong,WANG Yanguo,LI Xingjian(Nanjing NARI-Relays Electric Co.Ltd.,Nanjing 211102,China);Automated Testing System for IED[J];Automation of Electric Power Systems;2009-08
9 WANG Zhou, ZHANG Ming, SUN Ling sheng, CHEN Chen, DING Yi (Electrical Power College, Shanghai Jiaotong University, Shanghai 200030,China);Research on DSP Based Digital Test Equipment for Protection Relay by Dynamic Simulation[J];Electric Power Automation Equipment;2001-02
10 CHEN Hao (Sichuan University,Chengdu 610065,China);Test device of protective relay and its property[J];Electric Power Automation Equipment;2002-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved