A fault feeder selection method for resonant grounding system based on transient amplitude fault measure

YAN Guangtai;LIANG Jiawen;WANG Xintao;LIU Anhua;Liaocheng Power Supply Company;  
In order to accurately detect single-phase ground fault in resonant grounding systems,a fault line selection method based on fault transient amplitude measure is proposed.With the modulus transform,feeder fault and normal feeder after fault are analyzed.By using wavelet modulus maxima characteristic current,the law of zero mode initial current wavelet modulus maxima is developed.The transient amplitude fault measures are defined combined with this law and the general fault measures.The transient amplitude fault measure of the fault feeder is maximum,and the normal ones is greater than 0 and close to 0.Accordingly,the fault line selection method is proposed and the fault feeder is detected.Theoretical analysis and ATP simulation results show that,this method can effectively detect single-phase ground fault in resonant grounding systems,and is not influenced by arc suppression coil.
【CateGory Index】: TM73;TM862
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 7 Hits
1 Li Bin Shu Hongchun(Kunming University of Science and Technology Kunming 650051 China);A New Integration Method of Fault Line Detection in Resonant Earthed System Based on Instantaneous Real Power and Instantaneous Virtual Power[J];Transactions of China Electrotechnical Society;2012-06
2 Jia Qingquan Shi Leilei Wang Ning Dong Haiyan(Key Lab of Power Electronics for Energy Conservation and Motor Drive of Hebei Province Yanshan University Qinhuangdao 066004 China);A Fusion Method for Ground Fault Line Detection in Compensated Power Networks Based on Evidence Theory and Information Entropy[J];Transactions of China Electrotechnical Society;2012-06
3 QI Zheng,AI Xin,WANG Bing-ge,YANG Yi-han (Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education(North China Electric Power University),Changping District,Beijing 102206,China);EFFECTIVE DOMAIN OF FAULTY LINE DETECTION IN SMALL CURRENT GROUNDING SYSTEM BASED ON ROUGH SET THEORY[J];Power System Technology;2005-12
4 GUO Mou-fa, LIN Miao-yu, YANG Geng-jie (College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350108, China);The transient and steady-state information fusion method for single phase grounding line detection in resonant grounding system[J];Power System Protection and Control;2013-07
5 GAO Zhi-peng 1 , ZHANG Hui-fen 2 , SUN Xu-na 2 (1. Linpan Oil Extraction Plant, Shengli Oilfield Cooperation, Linpan 251507, China; 2. School of Automation and Electrical Engineering, University of Jinan, Jinan 250022, China);A method of fault line selection and fault point location with half-wave DC injection in distribution network[J];Power System Protection and Control;2013-13
6 ZHANG Guo-jun;REN Rong;HAN Jing-jing;TIAN Yong-feng;School of Electrical and Control Engineering, Liaoning Technology University;;Application of Hilbert transform in faulty line selection of distribution network[J];Power System Protection and Control;2014-10
7 ZHA Cong-mei;WANG Chang-jiang;WEI Yun-bing;LI Tao;LU Guang-hui;School of Electric and Information, Zhongyuan University of Technology;School of Electrical and Information Engineering, Zhengzhou University of Light Industry;Nanyang Power Supply Company;XJ Electric Co.,Ltd;;A new method of the resonant grounding system fault line detection based on EMD[J];Power System Protection and Control;2014-14
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;Survey of the Mthods of Fault Line Slection Based on Small Current Grounding System of Distribution Network[J];Anhui Electric Power;2010-02
2 Zhang Haiping He Zhengyou Zhang Jun (Southwest Jiaotong University Chengdu 610031 China);A Fault Line Detection Method for Indirectly Grounding Power System Based on Quantum Neural Network and Evidence Fusion[J];Transactions of China Electrotechnical Society;2009-12
3 PANG Qing-le1,2,SUN Tong-jing1,SUN Bo1,ZHONG Mai-ying1(1.School of Control Science and Engineering,Shandong University,Ji'nan 250061,China;2.College of Computer Science,Liaocheng University,Liaocheng 252059,China);Faulty line detection based on wavelet packet analysis for distribution network[J];Electric Power Automation Equipment;2007-04
4 LIN Qi-you1,CHEN Xing-ying1,WANG Zhi-wei2 (1.College of Electrical Engineering,Hohai University,Nanjing 210098,Jiangsu Province,China; 2.Jiangsu Electric Power Company,Nanjing 210024,Jiangsu Province,China);Application of Data Mining in Electricity Price Forecasting[J];Power System Technology;2006-23
5 PANG Qing-le,SUN Tong-jing,ZHONG Mai-ying (School of Control Science and Engineering, Shandong University, Jinan 250061, Shandong Province, China; Department of Physics, Liaocheng University, Liaocheng 252059, Shandong Province, China);New Criterion of Faulty Line Detection for Distribution Networks Based on Wavelet Packet Analysis[J];Power System Technology;2006-S2
6 CHENG Lu1,CHEN Qiao-fu2 (1.State Power Economic Research Institute,Xuanwu District,Beijing 100761,China;2.College of Electrical and Electronics Engineering,Huazhong University of Science and Technology,Wuhan 430074,Hubei Province,China);A Survey on Faulty Line Selection Technology for Single-Phase Grounded Transmission Line in Small Current Neutral Grounded System[J];Power System Technology;2009-18
7 PANG Qing-le1,2,SUN Tong-jing1,ZHONG Mai-ying1(1.School of Control Science and Engineering,Shandong University,Jinan 250061, China;2.College of Computer Science,Liaocheng University,Liaocheng 252059,China);Research on Fault Line Detection Device for Distribution Networks Based on the Rough Set Theory[J];High Voltage Engineering;2007-03
8 TANG Jinrui 1,2,YIN Xianggen 1,2,ZHANG Zhe 1,2,YANG Chen 1,YE Lei 1,QI Xuanwei 1,LIN Jin 1(1.State Key Laboratory of Advanced Electromagnetic Engineering and Technology,Huazhong University of Science and Technology,Wuhan 430074,China;2.Electric Power Security and High Efficiency Laboratory,Huazhong University of Science and Technology,Wuhan 430074,China);Survey of fault location technology for distribution networks[J];Electric Power Automation Equipment;2013-05
9 TIAN Yongmin(Army 92515,Huludao 125105,China);Built-in fuzzy information fusion algorithm application layer of wince[J];Journal of Liaoning Technical University(Natural Science);2013-05
10 Xiong Tingting 1 Zeng Xiangjun 1 Wang Yuanyuan 1 Ding Shengqiang 2 (1.Hunan Province Key Laboratory of Smart Grids Operation and Control, Changsha University of Science and Technology, Changsha 410114;2.Xiangtan Electric Power Information and Telecommunication Company, Xiangtan, Hunan 411101);Review of Earth Fault Feeder Detection Technology in Neutral Ineffectively Earthed Power Systems[J];Electrical Engineering;2013-05
China Proceedings of conference Full-text Database 1 Hits
1 PANG Qing-le, SUN Tong-jing, ZHONG Mai-ying ( School of Control Science and Engineering, Shandong University, Jinan 250061, Shandong Province, China; Department of Physics, Liaocheng University, Liaocheng 252059, Shandong Province, China);New Criterion of Faulty Line Detection for Distribution Networks Based on Wavelet Packet Analysis[A];[C];2006
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 CHENG Lu1,CHEN Qiao-fu2(1.State Grid Energy Research Institute,Beijing 100052,China.2.College of Electrical & Electronics Engineering,Huazhong University of Science and Technology,Wuhan 430074,China.);A New Fault-line-selection Method Based on Zero Sequence Instantaneous Power[J];Electrical Measurement & Instrumentation;2010-07
2 Shu Hongchun1 Peng Shixin2 Li Bin1 Zhao Xingbing3 (1. Kunming University of Science and Technology Kunming 650051 China 2. Kunming Power Supply Bureau Kunming 650011 China 3. Yunnan Electric Power Designing Institute Kunming 650051 China);Simulation After Detecting Fault Line in Resonant Earthed System Through Zero Sequence Current Motivation[J];Transactions of China Electrotechnical Society;2008-10
3 Liu Yihua1 Wang Yuanyuan1 Song Zhihuan1,2 (1. Ningbo Institute of Technology Zhejiang University Ningbo 315100 China 2. Zhejiang University Hangzhou 310027 China);Adaptive Fault Feature Extraction Based on Stationary Wavelet Packet Decomposition and Hilbert Transform[J];Transactions of China Electrotechnical Society;2009-02
4 Shu Hongchun1 Peng Shixin2 (1. Kunming University of Science and Technology Kunming 650051 China 2. Kunming Power Supply Bureau in Yunnan Power Grid Kunming 650011 China);A Fault Line Detection Algorithm for Distribution Network of Overhead Line and Underground Cable Mixed Lines Using S-Transform Energy From Short Window Data[J];Transactions of China Electrotechnical Society;2009-10
5 Zhang Haiping He Zhengyou Zhang Jun (Southwest Jiaotong University Chengdu 610031 China);A Fault Line Detection Method for Indirectly Grounding Power System Based on Quantum Neural Network and Evidence Fusion[J];Transactions of China Electrotechnical Society;2009-12
6 Xu Bo1 Zhang Jianwen1 Cai Xu1,2 Guan Shanlian3 Yao Yong4(1.Key Laboratory of Control of Power Transmission and Transformation Shanghai Jiao Tong University Shanghai 200240 China 2.State Key Laboratory of Ocean Engineering Shanghai Jiao Tong University Shanghai 200240 China 3.Henan Electric Power Testing and Research Institute Zhengzhou 450052 China 4.Kaifeng Power Supply Company Kaifeng 475003 China);Grounding Phase Determination in Non-Effective Grounding Systems in Case of Unsymmetrical Voltage[J];Transactions of China Electrotechnical Society;2011-12
7 Jia Qingquan Shi Leilei Wang Ning Dong Haiyan(Key Lab of Power Electronics for Energy Conservation and Motor Drive of Hebei Province Yanshan University Qinhuangdao 066004 China);A Fusion Method for Ground Fault Line Detection in Compensated Power Networks Based on Evidence Theory and Information Entropy[J];Transactions of China Electrotechnical Society;2012-06
8 XU Bing-ying, XUE Yong - duan, LI Tian - you, XIAN Ri - chang (Shandong University of Technology,Zibo 255049,China;Quanzhou Power Company, Quanzhou 362000,China;Zibo Power Company,Zibo 255032 ,China);Review of Line Selection of Grounding Fault in Non - Effectively Grounding Network Techniques[J];Electrical Equipment;2005-04
9 Xue Yongduan 1, Feng Zuren 1, Xu Bingyin 2, Chen Yu 2, Li Jing 2 (1. Xi'an Jiaotong University, Xi'an 710049, China; 2. Shandong Kehui Electric Co Ltd, Zibo 255031, China);EARTH FAULT PROTECTION IN NON-SOLIDLY EARTHED NETWORK BASED ON TRANSIENT ZERO SEQUENCE CURRENT COMPARISON[J];Automation of Electric Power Systems;2003-09
10 He Zhengyou, Qian Qingquan (Southwest Jiaotong University, Chengdu 610031, China);MOTHER WAVELET OPTION METHOD IN THE TRANSIENT SIGNAL ANALYSIS OF ELECTRIC POWER SYSTEMS[J];Automation of Electric Power Systems;2003-10
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved