Compare NRT threshold and behavior T-level in cochlear implant patients

TAO Yong1 ZHENG Yun1 WANG Kai1 MENG Zhaoli1 XU Ke1 XIE Tian2(1Hearing Center,Department of Otorhinolaryngology Head and Neck Surgery,West China Hospital,Sichuan University,Chengdu,610041,China;2Junda Trade Limited Company,Guangzhou)  
Objective:To learn the relationship between neural response telemetry(NRT) threshold and behavior T-level in cochlear implants patients and to learn how can we made NRT more useful for us to get the best map for cochlear implants who could not cooperate well to get the accurate behavior T-level.Method:Seventy-seven children implanted with the cochlear Nucleus 24 system.At each mapping procedure,vNRT threshold and behavior T-level of electrodes 1,6,11,16,20 were tested.After a time of experience and training,the children could cooperate well for test and the behavior T-level can be used for mapping.At the same time,vNRT and behavior T-level of the same electrode were recorded for statistic analysis.Result:Correlation coefficients(r) of vNRT and behavior T-level of each electrode were ranged from 0.40 to 0.54 respectively.The vNRT across each electrode ranged from 135 μV to 215 μV and the behavior T-level of each electrode ranged from 120 CL to 190 CL.The mean difference between vNRT and behavior T-level of electrode 1,6,11,16,20 were 27±14,24±13,31±14,26±13,20±13 respectively.The maximum difference between vNRT and behavior T-level was 65 and the minimum was-15.The group mean T-level is ranged from 148 CL to 159 CL and the group mean vNRT is ranged from 168 μV to 186 μV from electrodes 20 to electrodes 1.The NRT and behavior T-level both are going up higher a little bit from electrodes 20 to electrodes 1.Conclusion:NRT can be used to speculate the behavior T level for young child and adults who can not do behavior test.But because of the large individual difference,the result will not always be accurate.So,behavior T-level test should be the first choice for cochlear mapping patients.
【CateGory Index】: R764.5
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 CHEN Xueqing 1 HAN Demin 1 ZHAO Xiaotian 2 KONG Ying 1 LIU Sha 1 MO Lingyan 1 LIU Bo 1 ZHENG Jun 2 LI Yongxin 2 WANG Shuo 1 WU Yanjun 1( 1Department of Speech and Hearing Rehabilitation, Beijing Institute of Otolaryngology, Affiliated Beijing Tongren Hospital of Capital University of Medical Sciences, Beijing, 100005, China; 2 Department of Otolaryngology, Affiliated Beijing Tongren Hospital of Capital University of Medical Sciences);The psychophysical tests in different age of patients with cochlear implants[J];Journal of Clinical Otorhinolaryngology;2004-04
2 YANG Caihong1 ZHAO Dean1 CHEN Xueqing2 LIU Bo2LI Yongxin2 ZHENG Jun2 HAN Demin2(1Department of Otorhinolaryngology-Head and Neck Surgery, the First Hospital of Xiamen,Fujian Medical University,Xiamen,361003,China;2Beijing Institute of Otolaryngology,Tongren Hospital,Capital Medical University);The change of neural response telemetry thresholds in children with cochlear implant[J];Journal of Clinical Otorhinolaryngology Head and Neck Surgery;2007-13
3 CHEN Xueqing, HAN Demin, ZHAO Xiaotian, WANG Shuo, KONG Ying, LIU Sha, MO Lingyan, LIU Bo, WU Yanjun. Beijing Institute of Otolaryngology, Affiliated Beijing Tongren Hospital of Capital University of Medical Sciences, Beijing 100730, China Corresponding author: CHEN Xueqing;Comparison of neural response telemetry thresholds with behavioral T/C levels[J];Chinese Journal of Otorhinolaryngology;2002-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 HAN Dongyi (Department of Otolaryngology Head and Neck Surgery, China PLA General Hospital, Beijing, 100853, China);Archives of cochlear implantation in China[J];Chinese Archives of Otolaryngology-head and Neck Surgery;2004-01
2 CHEN Xueqing, HAN Demin, ZHAO Xiaotian, KONG Ying,LI Yongxin, LIU Sha, LIU Bo, MO Lingyan( Beijing Institute of Otolaryngology, Department of Otolaryn-gology Head and Neck Surgery, Beijing Tongren Hospital,Capital University of Medical Science,Beijing,100730,China);Comparison NRI thresholds and EARTs with M-Levels[J];Chinese Archives of Otolaryngology-head and Neck Surgery;2005-09
3 QIAO Xiaofeng;WANG Dong;LUO Xingmei;Department of Otolaryngology,Shanxi Provincial People's Hospital;;Study of NRT value characteristics with cochlear implants in children with malformed inner ear[J];Chinese Archives of Otolaryngology-Head and Neck Surgery;2014-01
4 MA Xiulan1 YAMAMOTO Sukiiti2 KUBO Takeshi2 (1Department of Otorhinolaryngology,the First Affiliated Hospital of China Medical University,Shenyang,110001,China;2Department of Otolaryngology and Sensory Organ Surgery Osaka University Graduate School of Medicine Osaka);Study on auditory event related potential with cochlear and hearing aid meanwhile[J];Journal of Clinical Otorhinolaryngology;2005-16
5 TAO Yong ZHENG Yun WANG Kai MENG Zhaoli XU Ke(Department of Otolaryngology,West China Hospital,Sichuan University,Chengdu,610041,China);Compare NRT value of straight electrode and contour electrode in Nucleus24 cochlear implant system[J];Journal of Clinical Otorhinolaryngology Head and Neck Surgery;2012-01
6 ;人工耳蜗电极在耳蜗内不同部位的NRT阈值[J];Zhejiang Clinical Medical Journal;2007-04
7 Han Demin (Department of Otorhinoloaryngology-Head and Neck Surgery,Beijing Tongren Hospital,Capital Medical University;Beijing Institute of Otolaryngology);Clinical Application and Research of Cochlear Implant[J];Journal of Capital Medical University;2007-06
8 ;Mapping technique in deaf children enter cochlear implantation[J];China Scientific Journal of Hearing and Speich Rehabi;2003-01
9 Kong Ying,Han Demin,Zhao Xiaotian,et al. ( Beijing Institute of Otolaryngology, Affiliated Beijing Tongren Hospital, Capital University of Medical Sciences, Beijing,100730, China);Characteristics and Changes of Comfortable Levels in Adolescent Patients after Cochlear Implants[J];Journal of Audiology and Speech Pathology;2006-06
10 Tian Ying;Pang Pai;Zhang Tao;Wang Zhixiang;Li Weiguang;Jiang Xuejun;Department of Otolaryngology,the First Affiliated Hospital of China Medical University;;The Intraoperative Analysis of SONATATI~(100) Cochlear Implantation[J];Journal of Audiology and Speech Pathology;2014-01
【Secondary Citations】
Chinese Journal Full-text Database 1 Hits
1 Xue Qing Chen1,De Min Han1, Xiao Tian Zhao2, Ying Kong1, Sha Liu1,Ling Yan Mo1, Bo Liu1, Jun Zheng2, Yong Xin Li2, Shuo Wang1,Yan Jun Wu1,1Institute of Otolaryngology, 2Department of Otolaryngology Head and Neck Surgery, Affiliated Beijing Tongren Hospital, Capital University of Medical Sciences, Beijing 100730, China;Characteristics of threshold and comfortable levels after artificial cochlear implantation[J];Chinese Journal of Clinical Rehabilitation;2004-32
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved