Research of Construction Cost Minimization Model for High Concentration Organic Wastewater Treatment with Fusant.
Li Weixin et al (Nanjing Institute of Environmental
Science, SEPA, NANJING 210042)
Based on the results of the study on the
multivariable optimal control of the high concentration organic wastewater biological treatment
system with Inter kingdom Fusant, the construction cost minimization model and the restriction
formulas were established and the optimization of process design was discussed. The results
of a case study of bean processing wastewater treatment with fusant showed that the
mathematical model has a sole solution on condition that three parameters were regarded as
control variables. The three parameters are: concentration of influent in aeration tank ( S
0),MLSS concentration in aeration tank ( X ) and recycle ratio ( R ). This model can be used as
reference to the process design of high concentration organic wastewater treatment.