Field measurement and analysis of indoor and outdoor VOC concentration for Changsha residential buildings

By Li Nianping ★,★Hunan University, Changsha, China Zhu Kongmin, Pan Yougui, Li Xiaohua, Fu Zhengrong, Yoshino Hiroshi, Akashi Mochida, Shigeno Takayuki, Ni Yueyong and Yukio Yanagisawa  
Based on the results of field measurement and questionnaire from ten households, presents the status of indoor and outdoor VOC concentration and personal exposure. Analyses the influences of environment temperature and humidity, hours of residence decoration and air flow distribution mode of air conditioning on the emission and distribution of VOC in residences.
【Fund】: 日本国文部科学省重大资助项目 (编号 :13 5 740 0 7)
【CateGory Index】: TU834
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 3 Hits
1 Zhang Jinping1, 2, Li Angui1 and Li Desheng2(1 School of Environment and Municipal Engineering, Xi'an University of Architecture & Technology;2 School of Environment and Municipal Engineering, Lanzhou Transportation University);The Study Development of Indoor Volatile Organic Compounds[J];Building Energy & Environment;2005-04
2 By Han Xu★, Wu Hongyu, Dou Wenping, Zhou Senlin and Zhang Hua★Tsinghua University, Beijing, China;Experimental study on pollutant elimination from indoor air in a new-decorated office[J];Heating Ventilating & Air Conditioning;2006-01
3 By Pei Qingqing~★,Zhou Zhiping and Liu HanxiangGuangzhou University, Guangzhou, China;Investigation on indoor environment for emporiums in Guangzhou[J];Heating Ventilating & Air Conditioning;2006-05
【Citations】
Chinese Journal Full-text Database 1 Hits
1 By Zhang Guoqiang ★, Song Chunling, Chen Jianlong and F.HaghighatHunan University, China;Volatile organic compounds:a kind of important indoor pollutants[J];Hv & Ac;2001-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LAN Li-juan et al(School of Environment and Material Engineering,Yantai University,Yantai,Shandong 264005);Study on the Ability of Plants Purifying Indoor Methylbenzene[J];Journal of Anhui Agricultural Sciences;2011-09
2 TANG Bo~1(1.Shanxi University of Technology,Hanzhong 723000,China);The Test and Control of Formaldehyde in House[J];Environmental Science and Management;2006-05
3 ZHANG Xiao-yong~1,HUANG Wei~2,SI Wei~3,LU Feng~4,WANG Zhen-hong~5(1.2.3.4 Jiangsu Environmental Monitoring Center,Nanjing?210036,China;5.Department of Chemistry and Environment Science,Zhangzhou Normal University,Zhangzhou?363000,China);Control and Actuality of the Air Pollution Indoor[J];Environmental Science and Management;2006-06
4 Zhang Xianhui1,Li Changyu2(1.Heilongjiang Academy of Environmental Sciences,Harbin 150056,China;2.Yichun Forestry Power Plant,Yichun 153011,China);Talking about the Problems of Indoor Environmental Pollution[J];Environmental Science and Management;2008-10
5 LIU Yu;SHEN Jun;ZHU Xiao-dong. College of Material Science and Engineering,Northeast Forestry University,Harbin,150040,P.R.China.;Effect of hot-pressing parameters on the emission of volatile organic compounds from particleboard[J];Journal of Beijing Forestry University;2008-05
6 Lu Zhigang,Zhang Guizhen,Li Xiang,Li Jianjun(Jiangsu Entry-Exit Inspection and Quarantine Bureau,Nanjing 210001,P. R. China);Research on Determination Method for Volatile Organic Compound Emissions from Coated Wood-based Panels[J];Journal of Northeast Forestry University;2009-10
7 Zheng Xiaohong1 Qian Hua1 Wang Ruzhu2 Dai Yanjun2(1School of Energy and Environment,Southeast University,Nanjing 210096,China)(2Institute of Refrigeration and Cryogenics Engineering,Shanghai Jiao Tong University,Shanghai 200240,China);Influence of bake out and ventilation on indoor distribution of VOC concentration[J];Journal of Southeast University(Natural Science Edition);2009-05
8 WEN Yuan-gao~(1,2), LIAN Zhi-wei~(1) (1. Institute of Refrigeration and Cryogenics, Jiaotong University, Shanghai 200030; 2.Wuhan University of Science and Technology,Wuhan 430070);VOCs Pollution in Indoor Air and Its Control[J];Environmental Science and Technology;2004-02
9 LI Tao,YAN Shao-hong(Shenzhen Municipal Environmental Monitoring Station,Shenzhen 518001);Indoor Decoration Pollution and Preventive Measures[J];Environmental Science and Technology;2004-04
10 WANG Shu-qin1, FAN Xue-juan2 (1.School of Environment Science and Engineering, North China Electric Power University, Baoding 071003; 2.Yantai Power Plant, Yantai 264002);Treatment of Formaldehyde from Indoor Air by Modified Activated Carbon[J];Environmental Science & Technology;2006-08
China Proceedings of conference Full-text Database 2 Hits
1 FAN Xinfang, MA Jun, WANG Chunxia (Huhhot environment monitoring centre, Huhhot 010030);The Analyze of Indoor Air Pollution and Measures to Control the Pollution[A];[C];2008
2 Wei Xiaoming, Wei Quanyuan, Wei Xiuying, Xiao Junhua, Cheng Xiaofu, Dong Renjie (College of Water Conservancy and Civil Engineering, China Agricultural University);Influence on indoor air quality by using different type of stove and fuel[A];Chinese Society of Agricultural Engineering[C];2006
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Zhang Hu(Anhui Institute of Arehitecture,Hefei,230022);INDOOR AIR POLLUTION AND ITS CONTROLLING OF DWELLING HOUSE[J];Journal of Anhui Institute of Architecture;2002-02
2 YU Dong FANG Zhen -dong WANG Jian LI Xu(University of Logistical Engineering,PLA,Chongqing 400016);Study on Indoor Air Quality[J];Journal of Chongqing Polytechnic College;2004-03
3 WANG Fei-feng ( Institute of Environmental Science,F ujian Teachers University,Fuzhou3 50 0 0 7,China);The Investigation and Countermeasures of Indoor Air Pollution Caused by Modern Ornamental Material[J];JOURNAL OF FUJIAN TEACHERS UNIVERSITY(NATURAL SCIENCE);2000-03
4 CHEN Bao-Ming WANG Bu-Xuan ZHANG Li-Qiang GENG Wen-Guang (Shandong Institute of Architecture and Engineering, Jinan 250014, China; Tsinghua University, Beijing 100084, China);NUMERICAL STUDY ON SORET-EFFECT AND DUFOUR-EFFECT IN POROUS ENCLOSURE[J];Journal of Engineering Thermophysics;2004-S1
5 PENG Yan 1, CHEN Di-yun 2, WANG Bo-guang 3, JIANG Lin-li 4 (1.School of Civil Engineering, Guangzhou University, Guangzhou 510405,China; 2.School of Biology and Chemistry Engineering,Guangzhou University,Guangzhou 510405,China; 3.Environmen;The Research of Volatile Organic Compounds (VOCs) in Some Hotels of Guangzhou City[J];Journal of Guangzhou University(Natural Science Edition);2002-05
6 GONG Xinyi\ BAI Yuhua\ YU Jiangping\ LU Sihua\ LI Jinlong (Department of Technical Physics,Peking University,Beijing\ 100871);The Research of Volatile Organic Compounds (VOCs) in the Buildings of Peking University Campus[J];Research of Environmental Sciences;1998-06
7 ZHAO Bin, CHEN Jiu-jiu, LI Xian-ting, et al. Department of Science for Architectural Technology, School of Architecture Science, Tsinghua University, Beijing 100084, China;Source, Effect and Distribution of Indoor Particulate Matter[J];Journal of Environment and Health;2005-01
8 ZHONG Ge-mei, CHEN Lie-xian. Guangxi Zhuang Autonomous Region Center for Disease Prevention and Control, Nanning, Guangxi 530021, China;Progress of the Study on Indoor Microbial Contamination and Anti-microorganism Technique[J];Journal of Environment and Health;2005-01
9 By Wang Daning, Yao Yang and Jiang Dong;Investigation and analysis of air quality in a underground Shopping center[J];Building Energy & Environment;2002-03
10 By Jiang Yantao,Wang Hai and Ye Biao;Indoor Air Quality Analysis and Measurements of Big Complex Commercial Centers[J];Building Energy & Environment;2003-04
【Secondary References】
Chinese Journal Full-text Database 8 Hits
1 PENG Yan1,2,SHEN Zhao-li1,CAO Xiao-an2(1.School of Water Resource and Environment,China University of Geosciences,Beijing 100083,China;2.School of Environment Science and Engineering,Guangzhou University,Guangzhou 510006,China);Pollution and Control of Volatile Organic Compounds in Indoor Air[J];Environmental Science & Technology;2008-06
2 CHEN Jin-ai,SUN Wei,ZHOU Yan-yu(Guangzhou Research Institute of Synthetic Materials,Guangzhou 510665,Guangdong,China);Review of Test Methods for Volatile Compounds from Synthetic Material's Aging in Simulative Human's Living Environment[J];Synthetic Materials Aging and Application;2008-03
3 NIU Hong-ya~1,et al(1.College of Resources & Safety Engineering,China University Mining & Technology(Beijing),Beijing 100083,China);The Partial Organic Compounds on Inhale Particle Matter in Indoor Air[J];Environmental Monitoring in China;2009-03
4 Zhang Xianping1,2,Hao Jinpeng3 and Shen Henggen1(1 College of Environment Science & Engineering,Donghua University; 2 Department of Electromechanical Engineering,Henan Institute of Technology; 3 Zhengzhou Zhongnan Real Estate Co.,Ltd.);Indoor Formaldehyde Pollution and Its Preventive Measures at Residential Homes in China[J];Building Energy & Environment;2007-03
5 Jiang Tao Zhang Shuangbao(College Of Material Science And Technology,Beijing Forestry University);Actuality And Prevention Measure Of Indoor Formaldehyde Pollution In Our Country[J];Forestry Science and Technology Information;2009-01
6 Han Zongwei,Wang Jia,Shao Xiaoliang,Zhou Senlin,Han Xu and Shi Wenxing Tsinghua University,Beijing,China;Characteristics and eliminating strategies of contaminants in urban underground spaces[J];Heating Ventilating & Air Conditioning;2009-11
7 Zhao Qiyue & Mu YingBeijing Municipal Environmental Monitoring Centre,Beijing 100044;Gaseous VOCs Emitted from Automotive Industry and Their Control Countermeasures[J];Automotive Engineering;2009-04
8 HUANG Zhi-jia,SHEN Jie(College of Civil Engineering,Anhui University of Technology,Ma'anshan 243002,China);Evaluation of Indoor Air Quality in Supermarket in Ma′anshan[J];Refrigeration Air Conditioning & Electric Power Machinery;2007-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved