Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Journal of Taiyuan Normal University(Natural Science Edition)》 2011-01
Add to Favorite Get Latest Update

Analysis of Indoor Air Quality in Public Places Investigations

Zhen Shili(Environmental Monitoring Station of Datong,Datong 037006,China)  
Objective to understand the part public indoor air quality in Datong,during late 2008 to early 2010,we monitored and analyzed quarterly six indoor indexes(CO,ammonia,formaldehyde,benzene,toluene,xylene).Result 1.Except ammonia and formaldehyde,co benzene,toluene and xylene are not exceeded,the pass rate of ammonia and formaldehyde were 81% and 94%,the phenomenon that ammonia exceeds standard limit exists generally,the lowest rate of pass occurred in large supermarket(72%),and large hotels were serious than the others.Result 2.Statistical analysis yearly found that ammonia and formaldehyde exceeds standard limit,mainly concentrated in the third quarter.Conclusion Major pollutants in 4 kinds of public places were ammonia and formaldehyde,temperature and humidity and the release of ammonia and formaldehyde are relevant;pollution in indoor air mainly comes from building and decoration materials,etc.
【CateGory Index】: X51
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 ;Ammonia Pollution of Indoor Fitment and Its Control Measures[J];Heilongjiang Environmental Journal;2006-03
2 ZHOU Lian,CHEN Xiao-dong,CHEN Yu-lian,et al.College of Public Health,Nanjing Medical University(Nanjing 210029,China);Effect of temperature and humidity from artificial wood-based board on formaldehyde emission[J];Chinese Journal of Public Health;2007-02
3 BAI Zhi-peng, WANG Zong-shuang, JIA Chun-rong, ZHANG Lian-zhong, ZHU Tan (College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China). China Environmental Science, 2003,23(2):117~121;Studies on the emission rule of ammonia from indoor concrete wall using environmental chamber[J];China Environmental Science;2003-02
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Yue Guanhua,Zhu Qing,Huang Zhongchen (School of Environment and Energy Engineering,BUCEA Beijing 100044);Monitoring and Control of Formaldehyde in Indoor Decoration[J];Journal of Beijing University of Civil Engineering and Architecture;2007-04
2 LI Xin1,SHI Jianping2,WEI Xiwen3,WANG Zhongqi4(1.Department of Resources and Environment,Mianyang Occupation Normal University,Mianyang 621000;2.Department of Materials Engineering,Mianyan Qccupation Technical College,Mianyang 621000;3.Institute of Chemical,Chongqing University,Chongqing 400045;4.Institute of Environmental,Southwest University of Science and Technology,Mianyang 621000);Study on Mathematical Model for Building Materials Affecting Indoor Air Quality[J];Journal of Changchun University of Science and Technology(Natural Science Edition);2007-01
3 WANG Zongshuang,YU Huan,BAI Zhipeng,ZHU Tan (College of Environmental Sciences and Engineering,Nankai University,Tianjin300071,China);Progress of Indoor Air Quality Related Standards and Assessment Methodology[J];Urban Environment & Urban Ecology;2003-04
4 MA Cui-mei,BAI Zhi-peng,GUAN Ze,GUO Ting(State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention andControl,College of Environmental Science and Engineering,Nankai University,Tianjin 300071,China);Influence of Ammonia and Oxidized Products of Ammonia on Photocatalytic Degradation of Toluene by TiO_2/ACF[J];Urban Environment & Urban Ecology;2008-05
5 ZAHGN De-rong,TAO Hua,ZHANG Xiu-rong(Department of Neurology,Yibin Second People′s Hospital,Sichuan 644000,China);Study of prevention of cerebral apoplexy patients′ intubation feeding complications by modified intubation feeding[J];Chongqing Medicine;2008-14
6 Shun Huizhen, Wang Yongxiu, Cheng Ying, Li Na. People's Hospital of Laiwu 271100, Shandong P.R.China.;Study on Sterilization of MR Coils[J];;2003-06
7 Qin Yuenan 1, Lei Zhaohui 2. 1.the People's Hospital of Hunan,Changsha,410002,Hunan,P.R.China; 2.the Second People's Hospital of Shenzhen, Shenzhen518035,Guangdong, P.R.China;Application of CO. Calamine Powder in Bedsore Nursing[J];;2004-04
8 LU Wenling,LUO Yanfang,YANG An,CHENG Wenjing.Department of Gastroenterology,Shenzhen Hospital Peking University,Shenzhen 518036,Guangdong;Effects of clysises with vinegar in different catheter depths on hepatic encephalopathy[J];Clinical Medicine;2006-07
9 DENG Cuilan, HUANG Xueling (Yong Feng people's hospital, Jiangxi province 331500, Jimei hospital of Xiamen city, Fujian province 361021);The medical practice in helping cure babie's pneumonia with fog-in-take with different medicine[J];Journal of Pediatric Pharmacy;2002-03
10 Huang Lin;Chen Wei;Zeng Xiudong;Hao Mingyan (452 Hospital of PLA610061);A Clinical Study on the Pressing blood Vessel Time after Intravenous Drip[J];JOURNAL OF NURSES TRAINING;1998-12
China Proceedings of conference Full-text Database 3 Hits
1 Zhipeng Bai Huan Yu Zongshuang Wang Yongchun Dong Tan Zhu College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071;Health Effect and Exposure Assessment of Ammoniain Indoor Air[A];[C];2004
2 Huan Yu Zhipeng Bai Ziqiu Su Zongshuang Wang College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071 School of Mathematical Sciences, Nankai University, Tianjin 300071;Modeling of Ammonia Emission from Indoor Concrete Wall with Antifreeze[A];[C];2004
3 Yongchun Dong, Zhipeng Bai, Liwen Zhang, Zongshuang Wang, Ting Guo, Tan Zhu College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071;Improvement of Ammonia Decomposition Efficiency of Polyester/Cotton Blend Fabric Coated with Nano TiO_2-Ag Photocatalyst[A];[C];2004
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Gong Sheng Huang Xiaorong (Department of Chemical Engineering, South China University of Technology, Guangzhou 510640) Sui Xiandong (College of Mechanical Engineering, South China University of Technology, Guangzhou 510640);Techniques for indoor air purification[J];Techniques and Equipment for Environmental Pollution Control;2004-04
2 YAN Yan, WANG Guangxue, YANG Xu, LIU Jie, LI Rui,LU Zhisong (College of Life Science, Central China Normal University, Wuhan 430079);A study on formaldehyde emission form artificial wood-based board[J];Acta Scientiae Circumstantiae;2003-01
3 Cu Xuelan et al;The Influence of the Indoor Ornamental Materials on the Indoor Air Pollution[J];Journal of Environment and Health;1992-02
4 XIA Zheng ying,SHE De hong,ZHAO Xia Yangzhou Sanitation and Anti-epidemic Station,225000;Status of Formaldehyde Pollution in Public Places Newly Decorated and Entering on Business in Yangzhou[J];Journal of Environment and Health;2000-05
5 ZHAO Ren zheng,JIN Nian zu,WANG Ke bo, et al. Institute of Applied Toxicology,Nanjing Medical University, 210029;Variation of Formaldehyde Concentrations in Indoor Air of Newly Decorated Office[J];Journal of Environment and Health;2002-02
6 JIA Shu-dui, CHANG Dou, WANG Sheng, et al. Changping District Center for Disease Control and Prevention, Beijing, Beijing 102200, China;Effect of Relative Humidity on the Concentrations of Formaldehyde and Ammonia in Indoor Air After Decoration[J];Journal of Environment and Health;2005-01
7 SHAO Ming-kun (Department of chemistry,Linyi normal college,Linyi Shandong 276005,China);Releasing Mechanism and Reducing Measure of Formaldelyde in plywood[J];Journal of Huaiyin Industry College;2003-01
8 ZHU Ling 1,?WANG Xue-zhong 2,?LI Kai 2,?ZHOU Ze-xing 2 (1.China University of Mining Technology,Beijing 100083,China; 2.Chinese Academy of Environmental Sciences,Beijing 100012,China);A study of photocatalysis degradation ammonia using immobilized TiO_2 photocatalysts[J];Journal of Ningxia University(Natural Science Edition);2001-02
9 DAN De-zhong~1, TAN HE-ping~2, FANG Zheng~2(1.Department of Environmental Science and Engineering,Sichuan University,Chengdu 610065,China;2.National Institute of Measurement and Testing Technology,Chengdu 610021,China);Progress for indoor air quality and its assessment methodology researches in China[J];China Measurement Technology;2005-05
10 ZHANG Hua,ZHOU Shu-qiong,DAN De-zhong(Department of Environmental Science and Engineering,Sichuan University,Chengdu 610065,China);Progress on control techniques for indoor air purification[J];China Measurement Technology;2005-06
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved