Practice on energy-saving optimized operation of oxygen compressor

Lu Pengfei(Jilin Hangyang Gas Co.,Ltd.,Jinzhu Township,Longtan District,Jilin 132104,Jilin,P.R.China)  
Unbalance supply and demand of oxygen and uncertainty of blowing time of converter results in frequent high-pressure bleed of oxygen compressor,which not only wastes energy but also generates noise contamination.During steelmaking,advance loading of oxygen compressor,discontinuous manual unloading and rational lowering of the setting of exhaust pressure of ensures the safe and stable run of oxygen compressor,saves the energy and lowers noise.Here,the operation status of oxygen compressor is briefed and instructions to its optimized operation and the obtained effects are described.