Design of a two-phase flow experimental device for Coriolis mass flowmeter

Li Miao1,Xu Kejun1,2,Hou Qili 1,Fang Min1,Xiong Wenjun1,Liu Cui1(1.School of Electrical and Automation Engineering,Hefei University of Technology,Hefei 230009,China; 2.Engineering Technology Research Center of Industrial Automation,Anhui Province,Hefei 230009,China)  
According to the characteristics of Coriolis mass flowmeter,the gas-liquid two-phase flow experimental device is designed.This article mainly introduces the system composition of the experimental device,the main features and indicators,and the selection of important parts.The applications prove that the experimental device has reasonable design,perfect performance and accurate measurement ability.It can be used to simulate gas-liquid two-phase flow.
【Fund】: 安徽省高等学校省级教学研究项目“信号检测、处理及实现”系列课程理论和实践教学改革研究(2008JYXM207);; 合肥工业大学2008年教学改革研究项目“信号获取与处理”系列课程建设与研究生创新能力培养(YJG2008Y01);; “信号检测、处理及实现”系列课程安徽省省级教学团队
【CateGory Index】: TH814
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 5 Hits
1 XU Ke jun, YU Cui xin, SU Jian hui, CHEN Rong bao, LIU Jia jun (School of Electrical Engineering, Hefei University of Technology, Hefei 230009, China);Development of excitation circuit for Coriolics mass flowmeters[J];JOURNAL OF HEFEI UNIVERSITY OF TECHNOLOGY(NATURAL SCIENCE);2000-01
2 YU Cui xin, XU Ke jun, LIU Jia jun (School of Electrical Engineering, Hefei University of Technology, Hefei 230009, China);An improvement of signal processing method based on DFT for Coriolis mass flowmeter[J];Journal of Hefei University of Technology(Natural Science);2000-06
3 XU Ke-jun,ZHANG Han (Hefei University of Technology, Hefei, Anhui 230009, China);A Study on the Digital Signal Processing and Driving Method for Coriolis Mass Flowmeters[J];Acta Metrologica Sinica;2004-04
4 XU Ke-jun,XU Wen-fu (Hefei University of Technology, Hefei, Anhui 230009, China);Research on Analog Driving Methods of Coriolis Mass Flow Meter[J];Acta Metrologica Sinica;2005-02
5 ;A New Digital Coriolis Mass Flow Transmitter[J];Process Automation Instrumentation;2005-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Wang Shuai Zheng Dezhi Fan Shangchun Tian Jing(School of Instrument Science and Opto-electronics Engineering,Beijing University of Aeronautics and Astronautics,Beijing 100191,China);Design and realization of all digital closed-loop system of Coriolis mass flowmeter[J];Journal of Beijing University of Aeronautics and Astronautics;2011-07
2 YANG Jun*,GUAN Ke,LIANG Jia(School of Information Technology,Chang'an University,Xi'an 710064,China);DFT in the Research of Phase Difference Measurement in Coriolis Mass Flow Meter[J];Chinese Journal of Sensors and Actuators;2006-06
3 CHEN Ling(College of Information Technologies,Hebei University of Economics & Business,Shijiazhuang 050061,China);Development and application of new type of flowmeter[J];Transducer and Microsystem Technologies;2007-06
4 Xiong Maotao1,2 Zhao Pujun2 Yu Bo1 Deng Wanquan1 Yin Baolai2 Yang Xiujie2(1Key Laboratory of Fluid Machinery and Power Machinery,Xihua University,Chengdu 610039,China)(2National Institute of Measurement and Testing Technology,Chengdu 610021,China);Research of LNG dispensers verification device[J];Cryogenics;2011-06
5 Li Xianggang1 Xu Kejun1,2 (1. Institute of Automation, Hefei University of Technology, Hefei 230009, China; 2 .Engineering Technology Research Center of Industrial Automation, Hefei 230009, China);Research on non-linear amplitude control method of coriolis mass flow-tube[J];Journal of Electronic Measurement and Instrument;2009-06
6 Xiong Wenjun1 Xu Kejun1,2 Fang Min1 Hou Qili1 Liu Cui1 (1.School of Electric and Automation Engineering,Hefei University of Technology,Hefei 230009,China;2.Engineering Technology Research Center of Industrial Automation,Hefei 230009,China);Study on matching method of primary meter and transmitter in Coriolis mass flowmeter[J];Journal of Electronic Measurement and Instrument;2012-06
7 Liu Feng-xin,Guo Yi,Zeng Jian (Information Science and Technology College of Beijing University of Chemical Technology,Beijing 100029,China);The Design of Embedded Coriolis Mass Flow Transimitter[J];Electronics Quality;2006-01
8 ZHOU Bo1,REN Jian-xin1,ZHANG Peng2(1.College of Automation under Northwestern Polytechnical University,Shaanxi Xi′an 710072,China;2.Xi′an Dongfeng Machinery & Electronics Co.Ltd,Shaanxi Xi′an 710068,China);A fluid viscosity measuring method and the design of its measuring system based on the Coriolis mass flowmeter[J];Industrial Instrumentation & Automation;2008-04
9 LI Xiang-gang,XU Ke-jun,ZHU Yong-qiang (School of Electrical Engineering and Automation,Hefei University of Technology,Hefei 230009,China);Comparison between two types of PI controllers in non-linear amplitude control algorithm[J];Journal of Hefei University of Technology(Natural Science);2009-11
10 LI Wei,YANG Hui-yue,TU Ya-qing(Dept.of Logistical Information Engineering,LEU,Chongqing 401311,China);A Variable Step-size Direct Frequency Estimation Algorithm for Coriolis Mass Flowmeter[J];Journal of Logistical Engineering University;2011-06
China Proceedings of conference Full-text Database 3 Hits
1 Zhu Yongqiang~1 Xu Kejun~(1,2) Li Ye~1 Li Xianggang~1 LI Miao~1 Hou Qili~1 (1 School of Electrical and Automation Engineering Hefei University of Technology Hefei 230009 China; 2 Engineering Technology Research Center of Industrial Automation Hefei 230009 China);Hardware Design of Digital Coriolis Mass Flow Transmitter Based on DSP[A];[C];2009
2 Ni Wei Xu Kejun (Institute of Automation, Hefei University of Technology 230009);Research on Digital Signal Processing Methods for Coriolis Mass Flowmeters[A];[C];2001
3 SU Fen-hua,TU Ya-qing,ZHANG Hai-tao (Dept.of Information Engineering,Logistical Engineering University,Chongqing 400016,China);Present Status and Prospects of Time-varying Frequency Tracking Methods for Coriolis Mass Flowmeter[A];[C];2009
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 LOU Wen-zhong(School of Mechatronic Engineering,Beijing Institute of Technology,Beijing 100081,China);A Temperature Test System for Fuze under the Heat Shock Caused by Perfusion-Encapsulation[J];Journal of Test and Measurement Technology;2007-02
2 Ding Yukang(Huazhong University of Science and Technology,Wuhan 430074);Design of measurement and control system based on LabVIEW[J];Electronic Measurement Technology;2007-11
3 WANG Wen-bin,WU Wen-ying,LI Meng-su(College of Mechanical Engineering, DonghuaUniversity, Shanghai 200051);Development of drive-programme of DAQ of Non-NI Company in LabVIEW[J];Electronics Instrumentation Customer;2005-01
4 He Xuanqing~1 Cui Yansheng ~2 (~1Shanghai KROHNE Guanghua Instruments Co.,Ltd. Beijing Office 100029) (~2 Department of Physics Tsinghua University,Beijing 100084);APPLICATION FOR CORIOLIS FORCES IN FLOW MEASUREMENT[J];;2005-05
5 JIA Hui qin 1,GUO En quan 2,REN Feng yuan 2,LI Yu 3 (1.Xi'an Jiaotong University,Xi'an 710049,China;2.Shaanxi Hitech Electronic Co.Ltd,Xi'an 710075,China; 3.Factory of Electromagnetic valve,China);The development of a distributed flowmeter calibration system[J];Industrial Instrumentation & Automation;2001-03
6 Xu Kejun Lu Xunhong Chen Rongbao;Research of key technology in signal processing of Coriolis flowmeter with DFT method[J];INDUSTRIAL INSTRUMENTATION & AUTOMATION;1998-05
7 ZHOU Hua-ying(College of Pharmaceutical Commerce,Guangdong Pharmaceutical University,Guangzhou 510006,China);Method of the flowmeter calibration based on BP-GA intelligent algorithms[J];Information Technology;2006-05
8 XU Ke jun, YU Cui xin, SU Jian hui, CHEN Rong bao, LIU Jia jun (School of Electrical Engineering, Hefei University of Technology, Hefei 230009, China);Development of excitation circuit for Coriolics mass flowmeters[J];JOURNAL OF HEFEI UNIVERSITY OF TECHNOLOGY(NATURAL SCIENCE);2000-01
9 YU Cui xin, XU Ke jun, LIU Jia jun (School of Electrical Engineering, Hefei University of Technology, Hefei 230009, China);An improvement of signal processing method based on DFT for Coriolis mass flowmeter[J];Journal of Hefei University of Technology(Natural Science);2000-06
10 Xu Kejun, He Weimin, Chen Rongbao;INVESTIGATION OF A NEW METHOD FOR FLOWMEASURMENT IN PROCESS AUTOMATION INSTRUMENTATION-CORIOLIS MASS FLOWMETER[J];JOURNAL OF HEFEI UNIVERSITY OF TECHNOLOGY(NATURAL SCIENCE);1995-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved