Research on calibration method of testing system standby attitude

Zhang Weihong;Measurement quality management department of XAC;  
This paper studies for the calibration of aircraft detection tester standby attitude measurement system,aiming at the production metering equipment manufacturing the aircraft attitude parameters and system requirements.By analyzing the status,technical requirements for the backup flight attitude,a variety of produce in the full use of AHRS testing system simulation of signal,after the technical conditions of dynamic link,driver and data acquisition,complete the calibration of the standby AHRS all or multiple projects.Through the research of calibration on standby ahrs,to solve the actual calibration problem, guarantee and traceability requirements me-asurement characteristics of the test equipment.