Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《JOURNAL OF XIAMEN UNIVERSITY(NATURAL SCIENCE)》 2000-01
Add to Favorite Get Latest Update

The Development of a Phoneline-Based Distant Multi Parameter Monitoring System

YANG Qiang 1, WANG Bo liang 1, CHEN Yan pu 2, BIAN Zheng zhong 2 (1. Dept. of Compu Sci., Xiamen Univ., Xiamen 361005, China; 2. Inst. of Biomedical Engineering, Xi′an Jiaotong Univ., Xi′an 710049, China)  
Telemonitoring and home health care technique are both among the most important research areas in telemedicine. Because heart disease and high blood pressure disease are very dangerous and paroxysmal, telemonitoring and alarming for ECG wave and noninvasive blood pressure are just the most important applying domain. In this paper, the design of a phoneline based remote multi parameter care system that may combine real time monitoring and online guide for patients in danger is discussed. The central monitoring system coold be used to monitor up to eight patients` ECG, blood pressure and temperature through the phone line at the same time .The whole system may be used for the extending ICU/CCU outside hospital, corporating with the clinic to diagnose unreasoned palpitations, chest pain and syncope, as well as for monitoring and curing guide for highly dangerous patients with abnormal heart rhythm and high blood pressure. The central monitoring system is designed on Win9x OS, and because of the thorough use of the ActiveX controls which are based on the COM Model to design the communication module, the HR check module and the abnormal heart rhythm check module, the system is not only outstanding but robust also.
【CateGory Index】: R319
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 CHEN Zhen cheng 1,NI Li li 2,SU Ke ping 2,WANG Hong yan 2,JIANG Da zong 1 (1 Institute of Biomedical Engineering , Xi′an Jiaotong University,Shannxi Xi′an 710071;2 The 533th Hospital of PLA , Yunnan Kunming 650224);Design of a Cardiac Monitor in Terms of Parameters of QRS Complex[J];Space Medicine & Medical Engineering;2002-04
2 Xiong Wei Xie Cunxi Zhang Tie Zou Yanbiao (College of Mech. Engineering,South China Univ. of Tech.,Guangzhou 510640);Multiple Physiological Parameter Dynamic Tele-monitoring System Based on Internet[J];Computer Engineering and Applications;2006-10
3 WU Shui-cai,BAI Yan-ping,YANG Chun-lan,GAO Hong-jian(College of Life Science & Bioengineering,Beijing University of Technology,Beijing 100022,China);Development of telemonitoring system for the experiment teaching of biomedical signal processing[J];Experimental Technology and Management;2008-10
4 JIA Wen-juana,BAI Yan-pinga,SHENG Xiu-junb,WU Shui-caia(a.Biomedical Engineering Center;b.University Hospital,Beijing University of Technology,Beijing 100124,China);Development of Physiological Multi-parameters Telemonitoring System[J];China Medical Devices;2009-08
5 XU Ming,WANG Wen-sheng,ZHANG Li-xin,ZHOU Yu(Unit93356of PLA,Jinzhou121001);Applications designed for a tele-monitoring electrocardiogram system[J];Chinese Medical Equipment Journal;2003-11
6 WU Xiao-ming, WU Kai, CEN Ren-jing, ZENG Wei-jie*, ZHI Xiao-xing(Biomechanics Institute, South China University of Technology, Guangzhou 510641);Development of a multiparametric remote monitoring system for heart function[J];Chinese Medical Equipment Journal;2004-04
7 TANG Yan TANG Jing-tian LI Ling-yunGraduate School of Biomedical Engineering School of Info-Physics and Geomatics Engineering Central South University Changsha 410083;Design of an electrocardiographic telemetry system using GSM[J];Chinese Medical Equipment Journal;2004-11
8 JIANG Yong, XU Min-guang, QIU Bao-yue(General Hospital, the 2nd Artillery Department of the PLA, Beijing 100088);The design of a cardiac monitor able to measure QRS parameter[J];Chinese Medical Equipment Journal;2005-04
9 WU Kai, WU Xiao-ming (Biomechanics Institute, South China University of Technology, Guangzhou 510641);Research and implementation of real-time dynamic display of multiple physiological parameters[J];Chinese Medical Equipment Journal;2005-07
10 Wu Shuicai,Li Haomin,Bai Yanping,Du Fangfang(Biomedical Engineering Center,Beijing University of Technology,Beijing 100022,China);Design of multi-physiological parameters telemonitoring system[J];Chinese Journal of Scientific Instrument;2007-06
China Proceedings of conference Full-text Database 1 Hits
1 Wu Shuicai~1 Li Jia~2 College of life science & Bioengineering,Beijing University of Technology 100124;The Design of a Wireless ECG Tele-monitoring System[A];[C];2008
【Citations】
Chinese Journal Full-text Database 1 Hits
1 YuLun; Yang Xueji; FangFang; Liu Zhili(Fuzhou University)Wang Lina; Ke Wenyuan(Fujian Province Hospital);The development of CTTM-1000 distant electrocardiogram central ambulatory monitoring system[J];Chinese Journal of Medical Instrumentation;1997-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 JIANG Jian-fei, WENG You-ying, YU Lun (Department of Radio Engineering, Fuzhou University, Fujian Fuzhou 350002, China);The Real Time Sampling and Flow Displaying in Windows[J];JOURNAL OF FUZHOU UNIVERSITY(NATURAL SCIENCES EDTION);2000-01
2 DUJun,QIURui_xue;The Application of the PL2101in the Controlling system of Street Lamps[J];International Electronic Elements;2003-09
3 SHEN Yi,YUAN Ming-xin,QIN Shao-hua(Department of Mechanical Engineering,Huaiyin Institute of Technology,Huaian Jiangsu 223001,China);Control of JACK Biologic Robot Based on VB6.0[J];Journal of Huaiyin Institute of Technology;2006-03
4 Li Tingjun Chen Yihuan Lin Xueyuan ( Department of Electronic Engineering,NAEI,Yantai 264001);The System of Long-range Monitor Based on Communication Net[J];Communications Technology;2003-12
5 ;Design of Interface between Single-Chip Computer and MODEM and Its Implementation[J];CONTROL & AUTOMATION;2000-05
6 ;Design and Realization of Micro-computer Remote Measure System for Central Heating[J];Control & Automation;2002-04
7 GAO Song~(1,2),NI Yuan~1,ZHANG He-fang~1(School of Electronic Information Engineering,Xi'an Institute of Technology,Xi'an 710032,China;2.Northwestern Polytechnical University);The remote monitoring system based on MODEM[J];Journal of Xi'an Institute of Technology;2005-01
8 Li Tingjun Chen Yihuan Zhu Qiankun Zhang Gongxue (Naval Aeronautical Engingring Institute, Yantai,264001);The Realization of the Super-far-distance Communication Between Singlechip System[J];Modern Electronic Technique;2001-08
9 Miao Zhenkui;Xiao Yunxiang;Zhao Huimin (Tianjin University, Tianjing 300072);Development of a central monitoring system with phone-transmission[J];MODERN SCIENTIFIC INSTRUMENTS;1999-05
10 XU Ming,WANG Wen-sheng,ZHANG Li-xin,ZHOU Yu(Unit93356of PLA,Jinzhou121001);Applications designed for a tele-monitoring electrocardiogram system[J];Chinese Medical Equipment Journal;2003-11
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHAO Li; BAI Zhi-tao; WANG Peng; (Xi'an Sunfield Digital Science &Technology Co.,Ltd., Xi'an 710075, China);The multi-channel synchronal data collecting system based on USB[J];Semiconductor Technology;2000-06
2 WU Baoming\+1, PENG Jing\+2, PENG Chenglin\+2, ZHU Jianxin 1. 1\^Department 5 of Research Institute of Field Surgery, Chongqing 400042;2\^College of Bioengineering Chongqing University, Chongqing\ 400044;A Novel Blood Pressure Holter with Remote Data Transfer Capability[J];Beijing Biomedical Engineering;2002-04
3 LI Yimin, WANG Jiasen, ZHANG Yonghong, BAI Jing. Department of Biomedical Engineering,Tsinghua University, Beijing 100084;Design and Implementation of an Internet Based ECG and Blood Pressure Telemonitoring Center[J];Beijing Biomedical Engineering;2004-03
4 LIU Xiaodong,GUO Xingming,XIAO Shouzhong. College of Bioengineering,Key Laboratory of Biomechanics & Tissue Engineering(Chongqing University),Ministry of Education,Chongqing 400044.;Study and Implementation of Serial Data Communication in Bluetooth-based Heart Sound Sampling System[J];Beijing Biomedical Engineering;2005-01
5 YING Jun~1,CHEN Guangfei~1,YE Dan~2,ZHANG Haichuan~2. 1 Department of Biomedical Engineering,General Hospital of Chinese PLA,Beijing 100853;2 Electro()_-Engineering Department of Beijing Institute of Technology,Beijing 100081;Design of the Wireless Thermometer System[J];Beijing Biomedical Engineering;2006-01
6 CHEN Yiwei,ZHANG Yonghong,BAI Jing Department of Biomedical Engineering,Tsinghua University,Beijing 100084;Development of a portable ECG monitor based on bluetooth communication[J];Beijing Biomedical Engineering;2008-02
7 Zhang Pengpeng,Shen Delin,Zhang Yonghong,Zhou Xiaoqiang,Bai Jiang(Dept.of Electrical Engineering and Applied Electronics,Tsinghua Universtity,Beijing 100084);A Home Dynamic Blood Pressure Measurement Device forTelemornitoring Network[J];BEIJING BIOMEDICAL ENGINEERING;1998-02
8 ;Negative Temperature Coefficient Resistant (NTCR) Temperature Sensors[J];Sensor World;2001-07
9 Qin Xu1,Shao Genfu1,Chen Shangsong1,Dai Ti2(1.Guilin Institute of Electronic Technology,Guilin 541004,China;2.Zhejiang Institute of Technology,Hangzhou 310014,China);Development & application of universal serial bus(USB) for automatic test[J];Electrical Measurement & Instrumentation;2000-10
10 Zhang Tongxu(Beijing P&T Consulting & Design Institute Co., Ltd., Beijing 100035);3G and the Development Trend[J];Telecom Engineering Technics and Standardization;2006-04
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 PAN Julong1,2,LI Shanping1,WU Zhendong3,ZHANG Daoyuan21.College of Computer Science,Zhejiang University,Hangzhou 310027,China;2.Department of Computer,China Jiliang University,Hangzhou 310018,China;3.College of Comm.Eng.,Hangzhou Dianzi University,Hangzhou 310018,China;A Design of Secure Community Healthcare Monitoring System Based on Wireless Sensor Networks[J];Chinese Journal of Sensors and Actuators;2009-06
2 PAN Julong1,2* ,LI Shanping 1,ZHANG Daoyuan2 1. College of Computer Science,Zhejiang University,Hangzhou 310027,China; 2. Department of Computer,China Jiliang University,Hangzhou 310018, ( ) China;A Study of Two Algorithms Based on Feistel Cipher in Wireless Medical Sensor Networks[J];Chinese Journal of Sensors and Actuators;2010-07
3 JIN Ning,ZHANG Daoyuan,GAO Jianqiao,WANG Zhaofeng(College of Information Engineering,China Jiliang University,Hangzhou 310018,China);A Study on the Application of Symmetric Ciphers and Asymmetric Ciphers in Wireless Sensor Networks[J];Chinese Journal of Sensors and Actuators;2011-06
4 (School of Bioscience and Bioengineering, South China University of Technology,Guangzhou 510640,P.R.China)Wu,Kai Wu,Xiaoming;The Design and Implementation of Multiple Physiological Parameter Remote Virtual Measurement Instrument[J];;2006-01
5 LU WEI WU XIAOMING XIONG DONGSHENG WU KAI SUN SHOUJUN;Design and Implement of Multi-parameter Mobile Monitor Based on GPRS[J];;2007-08
6 ZHANG Xu-hong,HU Yue-qi,CUI Ze-shi(Laboratory Technology Center of China Medical University,Shenyang Liaoning 110001,China);Deployment Assessment of the Patient Physiological Monitor based on the Demands for Function of Clinical Procedures[J];Information of Medical Equipment;2007-04
7 JIA Wen-juana,BAI Yan-pinga,SHENG Xiu-junb,WU Shui-caia(a.Biomedical Engineering Center;b.University Hospital,Beijing University of Technology,Beijing 100124,China);Development of Physiological Multi-parameters Telemonitoring System[J];China Medical Devices;2009-08
8 HUANG Shu-tao Equipment Department,People's Hospital of Puning,Puning Guangdong 515300,China;Clinical Application and Development Features of Medical Monitor[J];China Medical Devices;2011-02
9 HUANG Bang-yu1, WU Xiao-ming1, LIU Yan-fang2(1.Institute of Biomechanics, South China University of Technology, Guangzhou 510641;2.Department of Computer, Yanshan University, Qinhuangdao, Hebei Province 350002);The design of the network database of tele-monitoring system[J];Chinese Medical Equipment Journal;2005-04
10 WU Kai, WU Xiao-ming (Biomechanics Institute, South China University of Technology, Guangzhou 510641);Research and implementation of real-time dynamic display of multiple physiological parameters[J];Chinese Medical Equipment Journal;2005-07
China Proceedings of conference Full-text Database 1 Hits
1 Chen zhencheng Zhang Lingzhi Gong qiong (Institute of Biomedical Engineering, School of Info-physics, Central South University, Changsha, 410083);Development of a Home-care Portable Apparatus for Detecting and Diagnosing[A];[C];2008
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 Zhu Ze-huang, Hu Guang-shu, Guo Heng,Cui Zi-jing (Qinghua Univetsity, Beijing );DEVELOPMENT OF MIT-BIH ECG DATA BASE ANDITS APPLICATION AS CHECK STANDARD[J];Chinese Journal of Biomedical Engineering;1993-04
2 Liang Haidong (Second System Institute of China Aerospace Company) Zhou Lixia (Beijing Jishuitan Hospital);R wave detecting device for γ camera[J];CHINESE JOURNAL OF MEDICAL INSTRUMEN TATION;1995-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved