Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Fire Science and Technology》 2014-01
Add to Favorite Get Latest Update

Spread property of window plume across the exterior wall of high-rise buildings in wind

YIN Chen-chen;LI Jun-mei;HU Cheng;XIAO Xiao-hui;LI Wei;College of Architecture and Civil Engineering,Beijing University of Technology;State Key Laboratory of Earth Surface Processes & Resource Ecology, Beijing Normal University;Safety & Emergency Management Lab,Beijing Municipal Institute of Labor Protection;  
The wind effects on the wind flame spread across the exterior wall of the high-rise building were studied by the numerical methods.The simulation was focused on the top 5 floors of a hotel,and the max fire power is 2 MW and 6 MW separately.The distribution of temperature and velocity vector of windows plume was obtained under different scenarios.The results showed that high wind speed will change the window flame spread direction and make the room inclined above the fire room more danger,especially the room at the same floor adjacent to the fire room.Special passive fire protection measures should be taken under these kinds of conditions.
【Fund】: 北京工程技术研究院建设专项项目“超高层建筑火灾人员疏散动态诱导系统”(PXM 2013-178304-000005)
【CateGory Index】: TU972.4
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 ZHU Jie 1,2, HUO Ran1, FU Yong-sheng2 (1.State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230026,China; 2.Institute of Environment Engineering,South-West Jiaotong University,Chengdu 610031,China);Smoke control in supertall buildings[J];Fire Science and Technology;2007-01
2 YANG Shu-jiang1,LI Yong2,YI Liang2 (1.Changsha Fire Detachment,Hunan Changsha 410008,China;2.Institute of Disaster Prevention Science and Safety Technology,Central South University,Hunan Changsha 410075,China);Study on mass flow rate of plume under horizontal wind[J];Fire Science and Technology;2009-07
3 LIANG Zhen-tao;LI Si-cheng;CHEN-WANG Hai-tao;LI Chang-hou;The Chinese People's Armed Police Forces Academy;;Numerical study of wind effects on the characteristics of flame[J];Fire Science and Technology;2013-09
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LU Lei HONG Ke-kuan YANG Qing-jun ZOU Yuan(Faculty of Safety Engineering,China University of Mining and Technology,Xuzhou 221008,China);High-Rise Building Fire Prevention and Control Measures and Research[J];China Public Security(Academy Edition);2010-02
2 TONG Guilai(Tianjin Public Security Fire Bureau Headquarts,Tianjin 300090,China);Fire Risk Analysis of High Building’s Typical Functional Zone on Numerical Simulation[J];China Public Security(Academy Edition);2011-04
3 ZHAO Linhuang,LIN Xi(Fujian Provincial Public Security Fire Corps,Fuzhou 350003);Study on Fire Control and Escape Safety of High-rise Buildings[J];Fujian Architecture & Construction;2012-10
4 YANG Shu-jiang (Changsha Fire Detachment,Changsha 410008,China);Performance-based Design of Smoke Management System of Large-space Building[J];Safety and Environmental Engineering;2010-05
5 XU Yan-qiu,WANG Zhen-dong(College of Resources and Environmental Engineering,Wuhan University of Science and Technology,Wuhan 430081,China);Study on evacuation simulation of fire ground based on pathfinder and FDS[J];Journal of Safety Science and Technology;2012-02
6 ZHAO Yao-hua1,LI Si-cheng1,2,WANG Wei2,DONG Xing-guo2(1.Department of Fire Commanding,The Chinese People's Armed Police Force Academy,Langfang 065000,Hebei,China;2.The College of Architecture and Civil Engineering,Beijing University of Technology,Beijing 100124,China);Study on Common Issues of Smoke Control System for Building[J];Building Science;2012-S2
7 YAN Zhi-jun,HU Yan,FENG Gang-qiang,ZHANG Guo,SHI Chao(Property Management Office of Changqing Xinglongyuan Community,Xi'an 710021,China);Fire Controlling Management System of High-Rise Office Building[J];Technology and Innovation Management;2013-02
8 HUANG Dong-mei1,ZHU Jie1,XIA Rui2,LI Jun1 (1.Department of Fire Protection Engineering,South-West Jiaotong University,Chengdu,610031;2.Chengdu Fire Detachment,Chengdu 610041,China);Numerical simulation of the effect of outdoor wind on the smoke movement inside of high-rise building vertical shaft[J];Fire Science and Technology;2007-06
9 WANG Song-lin (Sichuan General Fire Brigade,Sichuan Chengdu 610072,China);Discussion on the fire protection measures of respiratory glass curtain wall[J];Fire Science and Technology;2008-05
10 REN Tong, LUO Zhi-hong, YE Yi-fan (Xiamen Fire Detachment, Fujian Xiamen 361012, China);Experiences of evacuation design inside high-rise building[J];Fire Science and Technology;2008-06
【Secondary Citations】
Chinese Journal Full-text Database 9 Hits
1 Pan Yijie (Is economized in the basic construction engineering in advance final accounts examination centers in Fujian 350003);The Smoke Design Is Arranged to The High-building[J];Fujian Architecture & Construction;2003-01
2 QIU Yan , ZHOU Xin-quan ( College of Resources and Safety Engineering, China University of Mining and Technology, Beijing 100083, China);Integral models for fire buoyant plume and ceiling jets in horizontal roadway[J];Journal of Liaoning Technical University;2003-05
3 Chen Ying,Li Sicheng,Zhang Jingyan and Li Kaiyuan The Chinese People’s Ar med Police Force Academy,Langfang,Hebei Province,China;Effect of make-up air velocity on mechanical smoke exhaust efficiency in buildings with atrium[J];Heating Ventilating & Air Conditioning;2011-05
4 YI Liang,YANG Yang,LI Yong,XU Zhi-sheng(Institute of Disaster Prevention Science and Safety Technology,Central South University,Changsha 410075,China);Mass Flow Rate of Plume Under Horizontal Wind[J];Journal of Combustion Science and Technology;2011-06
5 XU Zhi-sheng, CHANG YU-feng, BAI Guo-qiang, ZHOU Qing (Institute of Disaster Prevention Science and Safety Technology, Central South University, Changsha Hunan 410075, China);Smoke Control in Tall Buildings[J];West-china Exploration Engineering;2003-12
6 ZHANG Bing-mei,LI Tao (Ya'an Fire Detachment, Ya'an 625000,China);Discussion on the fire risk andsafety management of high-rise building[J];Fire Science and Technology;2003-S1
7 CHEN Ai-ping1, CUI Xiao-xing2 (1. Chinese People's Armed Police Forces Academy, Hebei Langfang 065000, China; 2. Tangshan Fire Detachment, Hebei Tangshan 063000, China);Theoretical analyses and experimental studies of whirling flames in enclosure fires[J];Fire Science and Technology;2010-02
8 WANG Kai-quan,LE Lin,HUANG Yong,QI Jing-ji,ZHOU Qi (School of Environmental & Safety Engineering,Changzhou University,Jiangsu Changzhou 213164,China);Experimental study of gasoline fame propagation characteristic under tilt condition[J];Fire Science and Technology;2011-09
9 ZHANG Jing-yan,HUO Ran,WANG Hao-bo,FENG Rui(State Key Laboratory of Fire Science,USTC,Hefei 230027,China);Experimental study on the generation mechanism of stack effect[J];Journal of University of Science and Technology of China;2006-01