The application of fire ventilation in the fireground

XUN Di-tao;LI Si-cheng;WANG Wan-tong;Chinese People's Armed Police Forces Academy;  
In the fireground,the burning of the combustible which are in the room will create a lot of smoke.Smoke can cause asphyxia and poisoning,besides of this it can reduce occupants and firefighters' visibility.Therefore,An efficient smoke exhaust of the building in the fire,can not only provide an aid for the firefighters' rescue action,but also can increase the probability of the victims' surviving.Some measures of fire ventilation are introduced in this paper,which provides technical guidance for the firefighters' correctly using fire ventilation.
【Fund】: 国家自然科学基金资助项目(51278493)
【CateGory Index】: TU998.1
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 ZHAO Xia(Haidian District,Beijing Public Security Fire Brigade Fire Department,Beijing 100035,China);Fire Smoke Damage and Fire Protection Design Countermeasures[J];Construction & Design for Project;2011-09
2 SU Lin(Shanghai Fire Research Institute of MPS,Shanghai 200438,China);Research on the riding position of portable smoke exhaust fan[J];Fire Science and Technology;2012-01
3 LI Si-cheng;XUN Di-tao;WANG Wan-tong;The Chinese People's Armed Police Forces Academy;;The application of the positive pressure ventilation in fire fighting[J];Fire Science and Technology;2013-09
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LI Yi-bo(The fire brigade of Hefei,Hefei,230088);The reason and prevention measures of automobiles[J];Journal of Anhui Institute of Architecture & Industry(Natural Science);2007-01
2 ZHANG Lu E Erdengtu(Team of Postgraguate,Chinese People's Armed Police Force Academy,Langfang 065000,China);Distribution Research of Extinguishing Agent in Large Fire[J];China Public Security(Academy Edition);2011-01
3 ZHU Tuo(Team 3 of Graduates Forces,The Chinese People's Armed Police Forces Academy,Langfang 065000,China);Preliminary Study of the Fire Extinguishing and Rescue Plan for High-Rise Building Fire[J];China Public Security(Academy Edition);2011-03
4 YANG Qinran1 TAO Yiran2(1 Team of Postgraduate,Chinese People’s Armed Police Force Academy,Langfang 065000,China 2 Chengdu Public Security Fire Brigade Jintang Brigade,Chengdu 610400,China);Analysis of the Disaster Site Command of Information Technology Strategies[J];China Public Security(Academy Edition);2011-04
5 LIANG Yingxi DENG Li(Teams of Graduate Students,The Chinese People’s Armed Police Force Academy,Langfang 065000,China);Problems and Solutions of Combination of Fireman and Equipment[J];China Public Security(Academy Edition);2011-04
6 LIU Zhihua(Liaoning Provincial Yingkou Fire Department Headquarters,Yingkou 115002,China);Discussion on the Personnel Survival Method and Way in the High-Rise Building Fire[J];China Public Security(Academy Edition);2011-04
7 KANG Na HUANG Fei (Teams of Graduate Students, Chinese People’s Armed Police Force Academy, Langfang 065000, China);Safety Management of the Firefighters in Disposa lof Hazardous Chemical Explosion Accidents[J];China Public Security(Academy Edition);2012-03
8 CHEN Qiang (Team One of Postgraduate, The Chinese People’s Armed Police Force Academy, Langfang 065000, China);Efficiency Evaluation of Oil Tank Fire Simulated Facilities[J];China Public Security(Academy Edition);2012-03
9 ZHANG;XingJing;Ningde Fire Brigade;;Hazards and Countermeasures of Flue Gas in Building Fire[J];China Public Security(Academy Edition);2014-01
10 XIA Deng-you,XIN Jing,CHENG Xiao-hong(The Chinese People's Armed Police Force Academy,Langfang 065000,China);Utility Model Study on Optimizing Operational Proposal of Firefighting & Rescue Command and Decision[J];Fire Control and Command Control;2008-06
China Proceedings of conference Full-text Database 4 Hits
1 WANG Changlin1, LI Jianhua2 (1.Chang Municipal Fire Brigade, Changde, Hu’nan Province 415000; 2.Department of Fire Commanding of the Armed Police Academy, Langfang, Hebei Province 065000);Research on the Optimized Combination of the First Due Force for Fire Fighting and Rescue[A];[C];2008
2 REN Shaoyun (Department of fire command, Chinese People’s Armed Police Force Academy, Langfang, Hebei China 065000);“Three-In-one” Place Fire Fighting[A];[C];2008
3 XIA Dengyou1, He Zhonghao2 (Department of Fire Command, the Chinese People’s Armed Police Force Academy, Langfang 065000, China; Dalian Municipal Fire Brigade, Dalian, 116001, China);Study on stage teaching mode of command education for fire & rescue[A];[C];2008
4 HUANG Jing (Department of Fire Command,Chinese People’s Armed Police Forces Academy,Langfang 065000,Hebei,China);The Research of Measures on Benzene Tanker’s Fire[A];[C];2009
【Secondary Citations】
Chinese Journal Full-text Database 7 Hits
1 LI Shan-ling,JIANG Yong,QIU Rong,CHEN Shan-shan(State Key Laboratory of Fire Science,University of Science and Technology of China,Hefei 230026,China);Fire smoke toxicity quantitative evaluation model THVCH and application[J];Journal of Safety and Environment;2012-02
2 LIU Fanga,b,ZHU Weia,WANG Gui-xueb(a.Faculty of Urban Construction and Environmental Engineering,b.Faculty of Biology Engineering,Chongqing University,Chongqing 400030,P.R.China);Biological toxicity effect of CO in fire smoke[J];Journal of Chongqing University;2009-05
3 LIU Yan-jun(National Research Center of State Administration of Work Safety, Beijing 100713, China);Smoke hazard and its controlling measures in building fire[J];Journal of Safety Science and Technology;2008-04
4 LIU Yan-jun(National Research Center of State Administration of Work Safety,Beijing 100713,China);Research on hazard assessment and dassification of building fire smoke based on BPNN[J];Journal of Safety Science and Technology;2008-06
5 WANG Li-jing,FU Jian-qiao(Shanghai Fire Research Institute of MPS,Shanghai 200438,China);Research on application of mobile smoke ventilation equipments in subway fire ground[J];Fire Science and Technology;2005-05
6 FENG Rui, HUO Ran, WANG Bing-ling, ZHANG Jing-yan (State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230026, China);Experimental study on the influencing factors of pressurization system in tall buildings[J];Fire Science and Technology;2006-02
7 XIA Qing1,YANG Sheng-lin2 (1.Yichang Municipal Fire Brigade,Hubei Yichang 443300,China;2.The Armed Police Academy,Hebei Langfang 065000,China);The impact of the volume of smoke exclusion on the flashover compartment fire[J];Fire Science and Technology;2008-03