Automatic Power Distribution Experimental System Based on IEC 60870-5-101 Protocol

Guo Kai Tao Weiqing (Department of Electrical Engineering and Automation in Hefei University of Technology, Hefei 230009)  
It's a SCADA system for distribution automatization. A SCADA software coded with VC++6.0 has been installed to the upper layer computer, so the computer can simulate and monitor the system, and make communication with the lower layer computer through the serial ports RS485. The lower layer computer is composed of automatic power distribution system remote terminal —— FTU, and it can supply lots of real-time data such as voltage, current, active power and reactive power to the server station. When some faults appear in lines, the FTU can detect it. Then the server station will search the locations, isolate the areas and reconfigure the distribution network. It has been proved that this set of equipment can imitate the industry control field as exactly as possible, and it's simple to manipulate and is very suitable for students to do experiments.
【CateGory Index】: TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 5 Hits
1 WANG Ting - liang (Taizhou Power Supply Company, Taizhou 225300, China);Present Situation and Development Trend of Distribution Automation System Terminal[J];Electrical Equipment;2004-12
2 ZHOU Nian-cheng , JIA Yan-hai , ZHAO Yuan (The Key Laboratory of High Voltage Engineering and Electrical New Technology, Ministry of Education, Chongqing University, Chongqing 400044, China) (Maanshan Power Supply Company, Maanshan 243000, China);Feeder Terminal Unit Based on System Protection to Distribution Network[J];Automation of Electric Power Systems;2006-08
3 ZHAO Hai-ying, ZHANG Jian-min ( School of Electronic Information, Hangzhou Dianzi University, Hangzhou 310018, Zhejiang Province, China );Application of IEC 60870-5-101 Telecontrol Protocol in Data Communication of Distribution Automation System[J];Power System Technology;2006-11
4 CHEN Shao-hua,YE Jie-hong,ZHENG Shuai (Faculty of Automation,Guangdong University of Technology,Guangzhou 510090,China);Study of arc suppression coil grounded system with medium resistance[J];Relay;2006-11
5 HU Fu-nian (School of Professional Technology,Xuzhou Normal University,Xuzhou 221011,China);Study of feeder terminal unit on DSP[J];Relay;2006-11
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 RONG De-sheng,LI Hong-zhu(College of Electrical & Control Engineering,Liaoning Technical University,Huludao 125105,China);Design of power supply model in power automation distribution network[J];Telecommunications for Electric Power System;2008-07
2 ZHANG Mingrui1,JIA Tinggang 2,XU Guoqing 1,JIN Lijun1,SUN Xianming 1(1.Tongji University,Shanghai 200092,China;2.Shanghai Electric Group Co.,Ltd.,Shanghai 200023,China);Development and implement of power plant SCADA system constructed by stages[J];Electric Power Automation Equipment;2008-07
3 LEI Lin-xu,QIN Jian,LIU Jing(China Electric Power Research Institute,Haidian District,Beijing 100085,China);Application of IEC60870-5-103 Transmission Protocols in Traveling Wave Based Fault-Detecting Equipment[J];Power System Technology;2007-S2
4 CONG Wei 1,PAN Zhencun 1,WANG Chengshan 2,YU Chunguang 1,WANG Wei 1,XUN Tangsheng 3,SONG Zhiming 3 (1.Shandong University,Jinan 250061,China;2.Key Laboratory of Power System Simulation and Control of Ministry of Education,Tianjin University,Tianjin 300072,China;3.Shandong Electric Power School,Tai'an,271000,China);A Substation Area Longitudinal Protection (SALP) Scheme for Distribution System with High DG Penetration[J];Automation of Electric Power Systems;2009-10
5 Jiang Weisheng (Haizi Coal and Electricity Company Ltd. of Huaibei Mining Group Company,Huaibei,Anhui 235000);Analysis and Comparision of Fault Line Detection Method for Non-effectively Earthed System[J];Electrical Engineering;2010-06
6 ZHOU Hong,LUO Xing,DENG Qijun(Department of Automation,Wuhan University,Wuhan 430072,China);Design of DSP-based FTU for RMU of intelligent distribution grid[J];Electric Power Automation Equipment;2011-02
7 HUANG Jian-hui;The Planning of Power Distribution System for Medium-sized and Small-sized Cities[J];Northeast Electric Power Technology;2009-06
8 ZHANG Li-guo a,WANG Bin a,LIU Jiang-tao b,LIU Yong-fu a,LIU Xing-long a(a.College of Information Science and Technology;b.College of Mechanical and Electric Engineering,Agricultural University of Hebei,Baoding 071001,China);Development of Data Acquisition System for Rural Network Distribution Transformer Based on GIS[J];Journal of Agricultural Mechanization Research;2008-07
9 HOU Yu-qiang1,GAO Yan-cheng1,ZHANG Xiao2(1.Shanxi Coking Coal Science & Technology Co.,Ltd.,Coal Management Company,Shanxi 030053,China;2.School of Information and Electric Engineering,China University of Mining and Technology,Xuzhou 221008,China);Simulation Analysis of the Arc Suppression Coil Grounding System Based on PSCAD[J];Colliery Mechanical & Electrical Technology;2011-01
10 DAI Yu(Guizhou Power Grid Corporation,Guiyang 550002,China);Application of Transient Travelling Waves to the Selection of Small-Current-Grounding Fault Feeder[J];Southern Power System Technology;2011-01
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Tan Wenshu (Electric Power Research Institute, 100085, Beijing. China);THE TRANSMISSION PROTOCOL OF DISTRIBUTION AUTOMATION SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-16
2 Zhu Xigui, Guo Zhihong, Jia Mingquan(Kehui Electric Co Ltd. Ji'nan 250061, China);TECHNOLOGY OF FAULT HANDLING IN FEEDER AUTOMATIONUSING COMMUNICATION CHANNEL[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-10
3 Zhao Zukang. Wang Wei(Naming Automation Research institute, Naming 210003, China);URBAN DISTRIBUTION AUTOMATION AND NETWORK STRUCTURE OPTIMIZATION IN CHINA[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-19
4 Chen Xinji. Shan Yuanda. Wu Jie (Southeast University. Naming 210096, China);A NEW FEEDER AUTOMATION SYSTEM BASED ON CAN BUS FOR DISTRIBUTION NETWORK[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-19
5 Lin Gongping Nanjing Autom ation Research Institute,Nanjing2 10 0 0 3,China;TECHNIQUE STRATEGY OF FEEDER AUTOMATION OF DISTRIBUTION POWER NETWORK[J];Automation of Electric Power Systems;2001-07
6 Cheng Ganjiang Electrical Power Research Institute of China,Beijing10 0 0 85 ,China;AN INTELLECTIVE SCHEME FOR PURSUANCE OF FEEDER AUTOMATION[J];Automation of Electric Power Systems;2001-09
7 Lin Gongping (Nanjing Automation Research Institute, Nanjing 210003, China);DISTRIBUTION AUTOMATION AND INTELLIGENT 10 kV SWITCHGEAR[J];Automation of Electric Power Systems;2002-11
8 Luo Jianbo, Hu Xilin (Nanjing Automation Research Institute, Nanjing 210003, China);NEW-TYPE DAT SERIES DISTRIBUTION AUTOMATION TERMINAL[J];Automation of Electric Power Systems;2002-13
9 Niu Peifeng 1, Li Guosheng 1, Liu Yuanlong 2, Liu Jianli 1, Wang Lihong 1, Zhou Liqin 1 (1. Qingdao Ocean University Engineering College, Qingdao 266071, China) (2. Qingdao Electric Power Bureau, Qingdao 266002, China);APPLICATION OF DIGITAL SIGNAL PROCESSOR IN DISTRIBUTION AUTOMATION TERMINAL UNIT[J];Automation of Electric Power Systems;2002-20
10 Lin Gongping, Xu Shiming, Luo Jianbo (Nanjing Automation Research Institute, Nanjing 210003, China);TECHNOLOGIES OF DISTRIBUTION AUTOMATION TERMINAL[J];Automation of Electric Power Systems;2003-12
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved