Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《China Medical Equipment》 2015-01
Add to Favorite Get Latest Update

Research on factors affecting operation rate of Tomo Therapy system and their countermeasures

ZHANG Jin-jian;LI Jing;WEN Ting;Tomotherapy Treatment Center,General Hospital of Guangzhou Military;  
Objective: To analyze the factors affecting operation rate of Tomo Therapy system, which had higher failure rate compared to the traditional accelerator. Relevant countermeasures had been proposed to increase the operation rate. Methods: To discuss the main factors affecting operation rate of Tomo Therapy, the failure record had been analyzed. Results: Temperature cooling system, compressed air system, deteriorating parts and database system had been summarized to be the main factors caused the failure of the Tomo Therapy. Conclusion: Some corresponding maintenance measures specific to the four factors had been proposed in order to reduce Tomo Therapy failure rate and increase Tomo Therapy service efficiency.
【Fund】: 广东省社会发展领域科技计划(2013B021800051)“非小细胞肺癌螺旋断层放疗食管损伤相关因素分析与预测”
【CateGory Index】: R815
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 WENTing,LIJing,ZHANGJin-jian,YU Yong-lan,YIN Zhi-yu,JIN Huai-zhi,WANG Ya-bing,YE Liu-qing Department of Helical Tomotherapy,Genenral Hospital of Guangzhou Military Area,Guangzhou Guangdong 510010,China;Daily Quality Control and Quality Assurance of Helical Tomotherapy[J];中国医疗设备;2013-07
2 MA Yong-zhong, WAN Ling, ZHANG Hong, FENG Ze-chen (Beijing Center for disease control and prevention,Beijing 100013, China);Application and radiation protection of helical tomotherapy[J];首都公共卫生;2013-03
3 LI Dong,SHANG Jin,YAN Ying,ZHANG Ren-cheng,WANG Dong-hui(Department of radiation oncology,Shenyang general hospital,Shenyang Liaoning 110015,China);Study on The Correlation Between Dosimetric Parameters Change and Degradation of Target for Tomotherapy System[J];中国医学物理学杂志;2013-02
4 SHI Bin-bin1,2,BAO Shang-lian1,ZHANG Yi-bao1,ZHANG Yue2(1.The Beijing City Key Lab of Medical Physics and Engineering,The Research Center for Tumor Diagnosis and Therapeutical Physics,Peking University,Beijing 100871,China;2.TomoKnife Company Limited,Beijing 100089,China);Method of Monitoring the Degradation of Tomotherapy System Target[J];中国医学物理学杂志;2012-05
5 LIU Xiao-zheng, YANG Jian-long China Association of Medical Equipment, Beijing 100044, China.;Evaluation of application of TOMO devices[J];中国医学装备;2012-09
6 SHANG Jin,LI Dong Radiation Therapy Department,General Hospital of Shen Yang military region,Shenyang Liaoning 110015,China;Current Status and Development Trend of Tomotherapy[J];中国医疗设备;2012-02
7 ZHANG Jin-bao (Biomedical Engineering Department,The Millitary General Hospital of Beijing PLA,Beijing 100700);Evaluation and Analysis of the Advantages in Helical Tomotherapy System[J];中国医疗设备;2009-04
8 Zhang Zhongzhu Beijing Zhongkanglian Medical Equipment Dev.Co.,Ltd,Beijing 100000,China.;Development in radiotherapy devices of china——development of accelerator in medicine in recent 30 years[J];中国医学装备;2009-02
9 JIANG Rui-yao, FU Shen (Radiotherapy Department of Sixth People’s Hospital affiliated to Shanghai Jiaotong University, Shanghai 200233, China);Perfect Combination of Linear Accelerator with CT Scanner——Helical Tomotherapy[J];中国医疗设备;2009-01
10 XU Shou-ping, DAI Xiang-kun, XIE Chuan-bin, YANG Yan,WANG Lian-yuan, GONG Han-shun, GE Rui-gang (Department of Radiation Oncology, PLA General Hospital, Beijing 100853, China);Measurement and Analysis of Beam Output Fluctuations for the Helical Tomotherapy System[J];中国医学物理学杂志;2009-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Tong Ying;Yin Yong;Chen Jinhu;Gong Guanzhong;Fu Lu;Gu Jiabing;Cheng Pinjing;School of Nuclear Science and Technology,University of South China;Radiation Physics Department of Shandong Cancer Hospital Affiliated to Shandong University;;Setup errors for the tumors in different parts of body with TomoTherapy[J];中华放射医学与防护杂志;2017-05
2 Cui Qinling;Sun Yan;Zhong Wen;Chen Yanzhi;Zhao Yuxia;Department of Radiation Oncology,the Fourth Affiliated Hospital of China Medical University;;Meta-analysis of dosemetric comparision between helical tomotherapy and intensity-modulated radiotherapy for early-stage postoperative breast cancer[J];肿瘤研究与临床;2016-12
3 HE Jian-jun;TIAN Xiao-yun;LIU Hai;HUANG Dong;LIU Jie;HAN Cheng-long;Department of Radiation Oncology,the 81st Hospital of PLA;;Research on Imaging Guidance in Helical Tomotherapy for Liver Carcinoma[J];中国医疗设备;2015-12
4 DING Yan-qiu;WU Wei-zhang;ZHU Fu-hai;National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention;;The comparison research on application on Arc CHECK and EBT3 film in dose verification of tomotherapy planning[J];中国医学装备;2015-09
5 ZHANG Jin-jian;LI Jing;WEN Ting;Department of Helical TomoTherapy, General Hospital of Guangzhou Military Area;;Research on configuration and maintenance of compressed air equipment in helical tomotherapy system[J];中国医学装备;2015-07
6 GONG Han-shun;WANG Jin-yuan;CONG Xiao-hu;YANG Tao;XIE Chuan-bin;GE Rui-gang;XU Wei;WANG Xiao-shen;JU Zhong-jian;XU Shou-ping;Department of Radiation Therapy, Chinese PLA General Hospital;;Dosimetry Analysis of Conformal Radiotherapy, Simplified Intensity Modulated Radiation Therapy and Helical Tomotherapy for Advanced Pancreatic Carcinoma[J];中国医学物理学杂志;2015-01
7 Ma Yongzhong;Yang Bo;Feng Zechen;Wang Hongfang;Wan Ling;Beijing Center for Disease Control and Prevention;Peking Union Medical College Hospital;;Study on dosimetric and radiation safety performance parameters of helical tomotherapy unit[J];中华放射医学与防护杂志;2015-01
8 ZHANG Jin-jian;LI Jing;WEN Ting;Tomotherapy Treatment Center,General Hospital of Guangzhou Military;;Research on factors affecting operation rate of Tomo Therapy system and their countermeasures[J];中国医学装备;2015-01
9 LIU Hai;HANG Xia-yu;LI Yi-kun;ZHANG Xin-liang;DING Wei;Department of Radiotherapy, The 81th Hospital of PLA;;Applicafion of OmniPro I' mRT Combined with Flatbed RGB Scanner in the Verification of Helical Tomotherapy Plans[J];中国医疗设备;2014-12
10 YANG Zong-xia;SHEN Jian-tong;LI You-ping;ZHAO Kun;SHI Cheng-hu;XIAO Yue;YU Jia-jie;GUO Wu-dong;LI Cui-cui;WANG Ying-qiang;LI Xiang-lian;Chinese Evidence-Based Medicine Center, West China Hospital, Sichuan University;National Health Development Research Center, Peking University;;Helical Tomotherapy for Cancer Treatment:A Rapid Health Technology Assessment[J];中国循证医学杂志;2014-09
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 MA Yong-zhong, WAN Ling,LOU Yun, LI Hui-juan, WANG Hong-fang, FENG Ze-chen (Beijing Center for Disease Control and Prevention, Beijing 100013, China);Protection designing and analysis of ahelical tomotherapy room[J];首都公共卫生;2012-06
2 CHEN Yong-dong Radiotherapy Center,Yangzhou Hongquan Hospital,Yangzhou Jiangsu 225200,China;Discussion on the Quality Assurance in Dose Calibration of Linear Accelerator[J];中国医疗设备;2012-06
3 SHANG Jin,LI Dong Radiation Therapy Department,General Hospital of Shen Yang military region,Shenyang Liaoning 110015,China;Current Status and Development Trend of Tomotherapy[J];中国医疗设备;2012-02
4 XU Shou-ping, DAI Xiang-kun, XIE Chuan-bin, YANG Yan,WANG Lian-yuan, GONG Han-shun, GE Rui-gang (Department of Radiation Oncology, PLA General Hospital, Beijing 100853, China);Measurement and Analysis of Beam Output Fluctuations for the Helical Tomotherapy System[J];中国医学物理学杂志;2009-01
5 XU Shou-ping, WANG Lian-yuan, DAI Xiang-kun, HUANG Hao, XIE Chuan-bin (General Hospital of PLA, Beijing100853, China);Principle and Application of Helical Tomotherapy[J];医疗卫生装备;2008-12
6 QU Bao-lin,XU Shou-ping,DAI Xiang-kun,ZHANG Hui-juan,CUI Shu-xiang,MA Lin(Department of Radiotherapy,PLA General Hospital,Beijing 100853,China);Research of helical tomotherapy for craniospinal radiation[J];军医进修学院学报;2008-02
7 LIAO Yu-lu,SONG Xiao-min,AO Fan,et al. Jiangxi Cancer Hospital,Nanchang,330029;The Short-term Clinical Observation of IMRT for 41 Treatment-naive Nasopharyngeal Patients[J];实用癌症杂志;2007-06
8 ZHOU Ying-juan, HUANG Shao-min, DENG Xiao-wu. Southern China State Key Laboratory of Oncology, Department of Radiation Oncology, Cancer Center, Sun Yat-sen University, Guangzhou 510060, China; Physics and Technology College of Wuhan University, Wuhan 430072, China;Radiochromic film in the dosimetric verification of intensity modulated radiation therapy[J];中华放射肿瘤学杂志;2007-04
9 JIANG Rei-yao(Clinical Engineering Dept.of Shanghai Sixth People's Hospital,Shanghai 200233,China);Digital device disposition for radiotherapy department[J];医疗设备信息;2006-12
10 SHEN Ya- li.Department of Radiotherapy, West China Hospital, Sichuan University, Chengdu 610041, China;Image guided radiotherapy system[J];国际肿瘤学杂志;2006-09
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved