DUAN Hui-ling;CHANG Qing-yu;Taiyuan Heavy Machinery Group Yuci Hydraulic Industry Co.,Ltd.;  
This paper mainly elaborates the reasonable design of hydraulic control one-way valve in the hydraulic system circuit,analyses the fault、the causation and the solution of hydraulic control one-way valve in the hydraulic system circuit on account of defective design,help to bring about high efficiency and energy conservation、safety and reliability of hydraulic system circuit.
【CateGory Index】: TH137.52