Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Electric Power》 2007-01
Add to Favorite Get Latest Update

Research on improving the transmitting capacity of transmission line based on dynamic monitoring

LING Ping1,JIN Heng1,QIAN Zhi-yin2(1.East China Power Test and Research Institute,Shanghai 200437,China;2.East China Power Grid Company Limited,Shanghai 200002,China)  
For improving the transmitting capacity of transmission line,the method of applying dynamic monitoring technology was presented after theoretical analysis,test and research in lab,and feasibility study based on field conditions.The method can help to improve the transmitting capacity,its main content includes: monitoring equipments which can monitor the conductor temperature,surrounding temperature,sunshine intensity settled on transmission lines' bottleneck points which have influence on transmitting capacity;the real-time current of transmission lines and their sections monitored by the real-time data system of operation center;the mathematic model which can transfer monitoring data into operation data and can be used by the operator for safe improving capacity operation.The transmission lines real-time transmitting rating management system has applied on several 500 kV and 220 kV transmission lines,the key part of the dynamic improving transmitting capacity technology is validated.
【CateGory Index】: TM764;TM726
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 3 Hits
1 ;The Study on the Dynamic Compatibilization Technology and Its Application of Empowerment of the Transmission Line[J];Anhui Electric Power;2009-01
2 ;Application of Technology of Capacity Increasing for Transmission Lines in Nanping Power Network[J];Electric Power and Electrical Engineering;2009-03
3 WANG Xuan,LI Hong,CONG Lin (Northwest Power Dispatching and Communication Centre,Xi’an 710048,Shaanxi Province,China);A Novel Monitoring System for High Voltage Transmission Lines Based on Wireless and Optical Communication Technologies[J];Power System Technology;2009-18
【Citations】
Chinese Journal Full-text Database 1 Hits
1 QIAN Zhi-yin, ZHANG Qi-ping (East China Power Grid Co., Shanghai 200002,China );Improving Transmission Ability of 500kV Lines in East China Power Network[J];Electrical Equipment;2005-10
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Tang Wei;Analysis and research to improve grid transmission capacity by reforming excitation system[J];Anhui Electric Power;2006-01
2 WANG Zhi-dong,LI Jun,QIU Wei-dong,LIU Jian-qin(State Power Economic Research Institute,Beijing 100761,China);Analysis on the Characteristics of Power Grid Development in the Period of 2000-2006[J];Electric Power Technologic Economics;2007-05
3 JIANG Weiyong1,ZHANG Boming1,WU Wenchuan1,LI Yuzhou1,WANG Hongyin2(1.State Key Lab of Power System,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.Dispatch Center of Henan Power Grid,Zhengzhou 450052,China);An Enhanced Control Method of Real-time Power Dispatch for Improving Transmission Capability[J];Automation of Electric Power Systems;2008-17
4 LIU Xiu-kuan, JIANG Wei-yong, ZHOU Su-quan, WANG Qi, LIU Zhuo, QU Zu-yi (School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, Heilongjiang Province, China;Liaoning Electric Power Company Limited, Shenyang 110006, Liaoning Province, China);Analysis on Power Flow Control Character of Interphase Power Controller[J];Power System Technology;2006-11
5 XU Qing-song,JI Hong-xian,HOU Wei,WANG Meng-long (Hangzhou Hikchina & Thunderbird Information Technology Ltd,China Electronics Technology Group Corporation No.52 Research Institute,Hangzhou 310012,Zhejiang Province,China);The Novel Technique of Transmission Line’s Capacity Increase by Means of Monitoring Conductor’s Temperature[J];Power System Technology;2006-S1
6 PAN Wei1,LIU Wen-ying1,YANG Yi-han1,SHI Ke-qin2,FAN Yue2 (1.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control (North China Electric Power University),Ministry of Education,Changping District,Beijing 102206,China; 2.Northwest China Grid Company Limited,Xi’an 710048,Shaanxi Province,China);Research on Operating Modes of 750 kV Northwest China Power Grid Electro-Magnetically Coupled with 330 kV Power Grid[J];Power System Technology;2007-15
7 CHEN Xi-ying,GUO Zhi-zhong (School of Electrical Engineering and Automation,Harbin Institute of Technology,Harbin 150001,Heilongjiang Province,China);A Pattern Recognition Based Approach to Extract Eigen-Data of Transmission Capability[J];Power System Technology;2008-01
8 PAN Wei1,LIU Wen-ying1,LI Yang-nan1,YANG Yi-han1,SHI Ke-qin2,FAN Yue2 (1.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control (North China Electric Power University),Ministry of Education,Changping District,Beijing 102206,China;2.Northwest China Grid Company Limited,Xi'an 710048,Shaanxi Province,China);Research on Improving Transmission Capability of Northwest China Power Grid by Use of Actually Measured Parameters of Excitation System[J];Power System Technology;2008-11
9 DING Jian1,ZHANG Wen-chao1,BU Guang-quan1,ZHANG Jian1,SHI Ke-qin2,WANG Meng2,ZHAO Qiang1(1.China Electric Power Research Institute,Beijing 100192,China; 2. Northwest China Grid Company,Limited,Xi'an 710084,China);Long Distance and Huge Capacity Transmission of Gansu Corridor Under Large-scale Wind Power Integration Circumstance[J];High Voltage Engineering;2009-08
10 ;Application of Technology of Capacity Increasing for Transmission Lines in Nanping Power Network[J];Electric Power and Electrical Engineering;2009-03
China Proceedings of conference Full-text Database 1 Hits
1 Du Zhiye Ruan Jiangjun Xiao Wei Yu Shifeng (School of Electrical Engineering,Wuhan University,Wuhan,Hubei 430072);Calculation of Ice-melting Current of High Voltage Over Head Line Based on Finite Element Method[A];[C];2008
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 LI Wei(College of Software Engineering,Chongqing University,Chongqing 400044,China);Development of Remote Wireless Communication Based on GPRS and SMS[J];Journal of Chongqing Institute of Technology(Natural Science Edition);2007-09
2 TU Shui-lin,XUE Zheng-ming (Dept.of Auto-control,Changshu Institute of Technology,Changshu 215500,China);Real Time Clock X1226 and The Design of Interface With Microcontroller 89C51[J];Journal of Changshu College;2005-04
3 LI Ye~1,JING Wei~(1,2) (1.Xuzhou Power Supply Company,Xuzhou 221002;2.Wuhan University,Wuhan 430072 China;);Operation Analysis of Extra High Voltage Transmission Line Series Compensation Capacitor[J];Power Capacitor;2006-04
4 Liu Changqing, Liu Shengchun, Chen Yongxiao, Guo Wenjian (SP Electric Power Construction Research Institute, Beijing, 100055);Test and Study on Increasing Allowable Temperature for Conductor Heating[J];Electric Power Construction;2003-08
5 Ye Hongsheng, Gong Dawei, Huang Weizhong, Zhao Junhu, Zhou Danyu, Shen Qian, Zhou Kang, Yuan Zhilei(East China Electric Power Design Institute, Shanghai City, 200063);Feasibility Study on Increasing Conductor Allowable Temperature and Engineering Practice[J];Electric Power Construction;2004-09
6 Ma Zhijian,Fu Chunheng (Beijing SG North China Electric Power Engineering Ltd.Co.,Beijing City,100011);Study on Application of 500 kV Compact-type Transmission Line Technology[J];Electric Power Construction;2005-10
7 XU Qing-song1, CHEN Ning2, HOU Wei1, WANG Meng-long1 (1. Haikang Thunderbird Information Technology Co., Ltd., Hangzhou,310012,China; 2. Chongqing Electric Power Corp., Chongqing 400014,China);Application of Transmission Line Dynamic Heat Rating Technology[J];Electric Power Construction;2007-07
8 QIAN Zhi-yin1,JIN HENG2 (1.East China Grid Co.Ltd.,Shanghai 200002,China;2.East China Electric Power Test and Research Institute Co.,Ltd.,Shanghai 200437,China);Transmission Line Capacity Increase Using Dynamic Monitoring Technology[J];Electric Power Construction;2007-12
9 HAN Fang1,XU Qing-song2,HOU Wei2,WANG Meng-long2(1.Thunderbird Software Co.Ltd.,Hangzhou 310023,China;2.Hik-Thunderbird IT Co.Ltd.,Hangzhou 310012,China);Application of Overhead Transmission Line Dynamic Ampacity Calculation Method[J];Electric Power Construction;2008-01
10 LIU Chang-qin, ZHANG Xue - zhe, LIU Sheng- chun, DONG Yu - ming, LI XIAO - qing (Electric Power Construction Research Institute, SG, Beijing 100055,China; Beijing Power Company, Beijing 100031,China);Discussion on Some Problems of Raising Permissible Operating Temperature of Conductor[J];Electrical Equipment;2004-08
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved