Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《CHINA MEDICAL DEVICES INFORMATION》 2000-02
Add to Favorite Get Latest Update

The Progress of Intracoronary Artery Stent

LI Tian-chang,HU Da-yi(The Heart Centre ofthe Beijing Red Cross Chaoyang Cross Chaoyang Hospital,Beijing 100020)  
With more then 300 patented stent designs available in the world, interventional cardiologists have had a very different range of experiences from their colleagues in this filed. With so many more stents availble, it raises an important issue; is a thorough knowledge of all available stents requaired to perform good interventional procedures, or, can we banifit from the experience of skilled colleagues, to select a few stents that can serve as our “workhores”? We believe it is the latter. This article is to offer the interventional cardiologists insights into the current experience with some most commonly used stents, and attempts to provide useful guidelines outlining the specific designs, indications and use of these stents. This article has been written to provide a conceptual framework for classifying, stents designs, recognizing the advantages and disadvantages of each, and for applying a particular design and stent to a specific coronary condition and lesion.
【CateGory Index】: R541
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 WANG Jialing1,3,CHEN Huayu2,CHEN Xi2,XIE Jijiang1(1 Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sicences,Changchun 130033;2 JiLin Radioand TV University,Changchun 130022;3 Graduate School of the Chinese Academy of Sciences,Beijing 100049);Finite Element Simulation of Coronary Stent Expansion Process[J];Materials Review;2009-20
2 Liang Dongke Yang Dazhi(School of Material Science and Engineering, Dalian University of Technology, Dalian 116023,China);Hemodynamics Analysis of Intravascular Stents with Different Design Features[J];Journal of Biomedical Engineering;2006-06
3 Zhang Zheng1,Zhang Xian2,Zhao Xiu-ling3,Jia Yue-ting4,Fu Wei5,Zong Li61Nangang Branch,Second Hospital of Heilongjiang Prov-ince,Harbin 150001,Heilongjiang Province,China;2ICU,Hospital of Yantai Economy Technology Devel-opment Zone,Yantai 264006,Shandong Province,China;3Department of Gynecology,4General Office,5Department of Respiratory Medi-cine,6Department of Neurology,Nangang Branch,Second Hospital of Heilong-jiang Province,Harbin 150001,Heilongjiang Prov-ince,China;Re-understanding of coronary artery stent[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2008-52
4 Yang Chun-yan1, Gu Zhao-yong2, Zhang Hong-bin1, Qiao Ai-ke1 1College of Life Science and Bio-engineering, 2College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing 100124, China;Numerical simulation research of the triangular cross-section structure flow resistance in endovascular stent[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2009-39
5 Kong Jing-jing,Zhang Hong-bin,Qiao Ai-ke College of Life Science and Bio-engineering,Beijing University of Technology,Beijing 100124,China;Numerical simulation of semi-circular section stent grafts[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2009-48
6 Lao Yong-hua,Zhi Xiao-xing,Lin Ze-feng,Li Xiao-nin,Cen Ren-jing,Huang Yue-shan School of Bioscience and Engineering,South China University of Technology,Guangzhou 510006,Guangdong Province,China;Optimal design of intravascular stent arc-strut element structure based on biomechanical performance[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2010-30
7 ZHAO Jun-hui,ZHANG Zhi-qing (Medical Equipment Testing Center in Shanxi Province,TaiYuan Shanxi 030012,China);Structure and Performance of Interventional Therapy Material[J];China Medical Devices;2009-02
8 TIAN Qiu-ju,HE Jin-sheng(The Second Hospital Affiliated to Shanxi University of Medical Sciences,Taiyuan030001)ZHANG Zhi-qing(Medical Equipment Institute of Shanxi Province,Taiyuan030012);Application development of interventional therapy material[J];Medical Equipment Journal;2003-07
9 WANG Lin,ZHANG Jin-zhong,HUANG Ti-gang.Tianjing Medical University,Tianjin 300070,China;Integrative Methods in Study of Restenosis in Coronary Stent[J];Medicine and Philosophy;2005-07
10 ZHANG Hong-Bin ZHANG Yun ZENG Kun QIAO Ai-Ke~*(College of Life Science and Bio-engineering,Beijing University of Technology, Beijing 100124,China);Hemodynamics Simulation of Intervention for Serial Saccular Aneurysm with Semi-circular Section Stent[J];Chinese Journal of Biomedical Engineering;2010-01
China Proceedings of conference Full-text Database 1 Hits
1 LI Ning, GU Yuan-xian (Department of engineer mechanics, Dalian University of Technology, Dalian 116024, China);Modeling and simplification of static analyses of coronary stent[A];[C];2005
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Xiao Bai,Cui Mingzhen,Yang Hua,Cai LiBeijing Institute of Labor Hygiene and Occupatinnal Diseases,Beijing 100020,P.R. China;SUPPRESSIVE EFFECTS OF ORGANIC RARE EARTH COM-POUNDS ON INDUCED SOS RESPONSES[J];CARCINOGENESIS, TERATOGENESIS AND MUTAGENESIS;1995-01
2 Liu Qingfeng1,Feng Shengshan1,Chu Heng2,Yan Haibiao2,Xu Shunhong1(1.Research & Design Instiuute of Mechanical & Electronic Engineering,Hubei University of Technology,Wuhan 430070,China;2.School of Chemical and Environmental Engineering,Hubei University of Technology,Wuhan 430068,China);RESEARCH AND PROGRESS OF MEDICAL BIODEGRADABLE POLYURETHANE[J];Engineering Plastics Application;2007-08
3 LI Ming1,REN Wei2,WANG Jun-tao2(1.Quanzhou Reserve Antiaircraft Regiment,Quanzhou 362000,China;2.Brigade of Postgraduate,Air Defense Forces Command Academy,Zhengzhou 450052,China);Optimal Ranking Method of Air Defense Forces’ Operational Proposal Based on Fuzzy Evaluation[J];Ordnance Industry Automation;2009-05
4 QIAO Ai-ke, LIU You-jun (College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100022, China);Simulation of Treatment for Aortic Arch Aneurysms With Half Implanted Stent[J];Journal of Beijing University of Technology;2007-04
5 QIAO Ai-ke LIU You-jun (College of Life Science and Bioengineering,Beijing University of Technology,Beijing 100022,China);Medical-application-oriented Hemodynamics Simulation(Ⅰ):Blood Flows in Arteries[J];Journal of Beijing University of Technology;2008-02
6 QIAO Ai-ke LIU You-jun GUAN Jian-chun ZHANG Hong-bin (College of Life Science and Bioengineering,Beijing University of Technology,Beijing 100022,China);Medical-application-oriented Hemodynamics Simulation(Ⅱ):Perspectives[J];Journal of Beijing University of Technology;2008-05
7 HE Fan LI Xiao-yang (College of Mechanical Engineering and Applied Electronics Technology,Beijing University of Technology,Beijing 100124,China);Numerical Investigation of Blood Flow in Arteries Under Different Boundary Conditions[J];Journal of Beijing University of Technology;2009-01
8 FU Ya, HUANG Yueshan, CEN Renjing, ZHI Xiaoxing. Biomechanics Institute , South China University of Technology, Guangzhou 510640,China;Research Progress of the NiTi SMA Stent in Intervention[J];Beijing Biomedical Engineering;2005-03
9 ZHANG Qingbao, WANG Weiqiang, QI Min, LIANG Dongke, YANG Dazhi.\ Department of Materials Engineering, Dalian University of Technology, Dalian, Liaoning Province\ 116024;Finite Element Analysis on the Crimped Mechanical Behavior of Coronary Stents[J];Beijing Biomedical Engineering;2006-04
10 GAO Bo\+1, HAO Sheng\|zhi\+1, DONG Chuang\+1, ZHOU Ji\|yang\+2eams, Dalian University of Technology, Dalian 116024; 2. Casting Center of Dalian University of Technology, Dalian 116023, China);Progress of Surface Treatment for Magnesium Alloys[J];Materials Protection;2003-10
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 FAN Wei1,GAO Fei2,3,XIE Jijiang2(1 Nanling Campus Test Center,Jilin University,Changchun 130021;2 Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,State Key Laboratory of Laser Interaction with Matter,Changchun 130033; 3 Graduate School of the Chinese Academy of Sciences,Beijing 100039);Study on Laser Fine Cutting Process of Stainless Steel Coronary Stent[J];Materials Review;2012-22
2 GUAN Bang-gui~1,MENG Hong-yun~2,LIAO Jian-hong~2,LIU Song-hao~2 (1.College of Science,Anhui University of Science and Technology,Fengyang 233100,Anhui,China; 2.Laboratory of Laser Processing Technology,South China Normal University,GuangZhou 510631,Guangdong,China);Fabrication and Influence Factors of Mental Cardiovascular Stent[J];Acta Laser Biology Sinica;2011-02
3 ZHANG Quanbin LIN Fan AO Ningjian MAO Xuan(Department of Biomedical Engineering,Jinan University,Guangzhou,510632,China);Progress on research of biodegradable conronary stents[J];Journal of Clinical Cardiology;2012-06
4 SHEN Xiang,REN Guo-dong,FENG Bao-lin(School of Mechanical Engieering,Jiangsu University,Jiangsu Zhenjiang 212013,China);Research on Optimal Design of Stent Foreshortening Mechanical Property[J];Machinery Design & Manufacture;2013-04
5 Wang Xingce1, Wu Zhongke1, Zhou Mingquan1, Luo Yanlin1, Shui Wuyang1, and Liu Xinyu2 1(College of Information Science and Technology, Beijing Normal University, Beijing 100085) 2(Advanced Computing Research Laboratory, Institute of Computing Technology, Chinese Academy of Sciences, Beijing 100190);Key Technologies of Vessel Segmentation and Reconstruction of the Cerebrovascular Disease Detection E-Health Platform Based on the Internet of Things[J];Journal of Computer Research and Development;2013-06
6 XU Jiang1,YANG Jie1*,YANG Ji1,YOU Tian-xue2,HUANG Nan2(1.School of Mechanics and Eng.,Southwest Jiaotong Univ.,Chengdu 610031,China; 2.School of Material Sci.and Eng.,Southwest Jiaotong Univ.,Chengdu 610031,China);Design and Develop of Vascular Stent Based on Finite Element Method[J];Journal of Sichuan University(Engineering Science Edition);2012-S2
7 SHI Gengqiang;SONG Xiaobing;School of Medical Instrument and Food Engineering,University of Shanghai for Science and Technology;;Finite Element Analysis of Intravascular Stent Based on ANSYS Software[J];Journal of Biomedical Engineering;2015-05
8 Zeng Wei-jie1, Ling You2, Zhi Xiao-xing21Department of Cardiovascular Medicine, the 421 Hospital of Chinese PLA, Guangzhou 510318, Guangdong Province, China; 2College of Biosci- ence and Bioengi- neering, South China University of Tech- nology, Guangzhou 510006, Guangdong Province, China;Biomechanics and biocompatibility characteristics of cardiovascular stents[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2008-13
9 Yang Chun-yan1, Gu Zhao-yong2, Zhang Hong-bin1, Qiao Ai-ke1 1College of Life Science and Bio-engineering, 2College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing 100124, China;Numerical simulation research of the triangular cross-section structure flow resistance in endovascular stent[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2009-39
10 Lao Yong-hua,Li Xiao-nin,Zhi Xiao-xing,Wu Jia-jie,Cen Ren-jing,Huang Yue-shan School of Bio-science and Bio-Engineering,South China University of Technology,Guangzhou 510006,Guangdong Province,China;Biomechanics experiment addressing cross-section shape of intravascular stent structure[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2009-43
China Proceedings of conference Full-text Database 1 Hits
1 Youjun Liu Aike Qiao Jinli Ding(Biomedical Engineering Center,Beijing University of Technology,Beijing,100124);Heomodynamics and its Medical Application[A];[C];2010
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved